Fisher Scientific Digital Vortex Mixer, Cat. # 02215418
The Fisher Scientific Digital Vortex Mixer, Cat. # 02215418 offers variable digital speed control from 500 to 3,000 RPM with continuous or touch mode operation. The microprocessor control within this vortexer maintains the user’s set point for strong, consistent mixing action. A digital timer is also featured, which will display elapsed time or, when programmed to user defined time limit, the unit will shut off when the time reaches zero. The continuous mode can be operated when using optional accessory attachments and the touch mode activates mixing when depressing the cup head. This vortexer also operates on an orbit of 4.9mm (0.194 in.).
The Fisher Scientific Digital Vortex Mixer, Cat. # 02215418 includes:
- > Rubber Dimpled Head
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Fisher Scientific Digital Vortex Mixer, Cat. # 02215418 Specifications
Speed Range
|
500 to 3,000 RPM (1,000 to 3,000 RPM on touch mode)
|
Orbit
|
4.9mm (0.194 in.)
|
Timer
|
1 second to 9999 minutes
|
Dimensions (L x W x H)
|
8 x 4.75 x 5.3 in. (20.3 x 12.1 x 13.5 cm)
|
Weight
|
10 lb. (4.5kg.)
|
Electrical Requirements
|
120V, 50/60Hz, 135W, 1.2A
|
- Verify power supply and PCB output correct, stable voltages across all required circuits
- Confirm the correct platform head is installed according to specifications
- Inspect the display for dim or dead pixels, replacing any compromised sections to maintain clear visibility
- Confirm full functionality of all buttons and knobs, ensuring accurate input response
- Verify that touch, pulse, and continuous modes operate fully and as intended
- Inspect all internal wiring for breakages, tears, or wear, replacing any underperforming components to ensure reliability
- Disassemble and thoroughly clean the internal casing to remove any accumulated debris
- Check that the feet are intact and confirm the vortexer is properly balanced on a flat surface
- Conduct a comprehensive cosmetic inspection to ensure all exterior surfaces meet quality standards
Technician Inspection and Recertification Checklist: Vortexer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Verify power supply and PCB output stable, correct voltages across circuits
|
Completed
|
|
Confirm correct platform head is installed according to specifications
|
Completed
|
|
Inspect display for dim or dead pixels; replace compromised sections for clarity
|
Completed
|
|
Confirm functionality of all buttons and knobs for accurate input response
|
Completed
|
|
Verify full operation of touch, pulse, and continuous modes as intended
|
Completed
|
|
Inspect internal wiring for damage; replace underperforming components for reliability
|
Completed
|
|
Disassemble and clean internal casing to remove accumulated debris
|
Completed
|
|
Check feet for integrity and confirm vortexer is balanced on flat surface
|
Completed
|
|
Conduct comprehensive cosmetic inspection to ensure quality of exterior surfaces
|
Completed
|
|