Eppendorf Vacufuge 5305 Plus Concentrator Complete System (Newest Version)
The Eppendorf Vacufuge 5305 Plus Concentrator Complete System (Newest Version) is designed to efficiently and gently concentrate DNA, RNA, nucleotides, proteins, and other samples using advanced heating technology and a fixed maximum speed of 1,400 RPM. Temperature settings include ambient, 30°C, 45°C, and 60°C, while the timer offers settings from 1 minute up to 9 hours and 59 minutes, or continuous operation. Achieving an ultimate vacuum of less than 20 mbar (15 Torr), the system includes a solvent-resistant, oil-free PTFE diaphragm vacuum pump. The durable coated lid enhances chemical resistance against many acids and organic solvents, making the Vacufuge plus a reliable and ergonomic solution suitable for any laboratory environment.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Eppendorf Vacufuge 5305 Plus Concentrator Complete System (Newest Version) includes:
- > F-45-72-8 Fixed Angle Rotor
- > Built-in Diaphragm Pump
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Eppendorf Vacufuge 5305 Plus Concentrator Complete System (Newest Version) Specifications
Maximum Speed
|
1,400 RPM (Fixed)
|
Temperature Setpoints
|
Ambient, 30°C, 45°C, 60°C
|
Timer
|
1 minute to 9 hours, 59 minutes, or continuous
|
Ultimate Vacuum
|
< 20 mbar (15 Torr)
|
Rotor Capacity
|
72 x 0.5 ml
|
Noise Level
|
< 50 dB(A)
|
Protection Class
|
IP54
|
Dimensions (W x D x H)
|
12.6 x 20.9 x 11.7 in. (33 x 58 x 29 cm)
|
Weight
|
68.3 lb. (31.5 kg)
|
Electrical Requirements
|
120V, 50/60Hz, 5.6A, 400W
|
- Inspect the display panel, replacing any dim or dead pixels to ensure clear visual feedback
- Verify full functionality of all buttons, confirming consistent responsiveness
- Examine the acrylic or glass lid for any cracks or chips, ensuring safety and integrity
- Check the vacuum chamber seal for any tears or cracks that could impact pressure retention
- Test chamber lid functionality, confirming all micro switches report a consistent .04 Ohms
- Verify external connections to the pump or cold trap, ensuring they are properly sealed and leak-free
- Inspect and clean the internal fan and condenser (if applicable) for efficient cooling and airflow
- Examine all internal wiring for frays or breakages, confirming secure and intact connections
- Test motor functionality, replacing motor or bearings if performance is compromised
- Inspect internal pump seals, replacing any worn or damaged seals to maintain vacuum integrity
- Inspect all internal hoses for potential leaks, ensuring tight, clean seals
- Confirm unit is capable of achieving all manufacturer-specified temperature ranges
- Verify the unit can reach specified vacuum levels in accordance with manufacturer standards
- Conduct a 6-8 hour cycle test to confirm consistent operational performance
Technician Inspection and Recertification Checklist: Centrifugal Evaporators
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display panel for dim or dead pixels
|
Completed
|
|
Confirm functionality of all buttons
|
Completed
|
|
Check acrylic/glass lid for cracks or chips
|
Completed
|
|
Inspect vacuum chamber seal for tears or cracks
|
Completed
|
|
Confirm chamber lid micro switches report .04 Ohms
|
Completed
|
|
Verify pump or cold trap connections are sealed and leak-free
|
Completed
|
|
Inspect and clean internal fan and condenser (if applicable)
|
Completed
|
|
Inspect internal wiring for frays or breakages
|
Completed
|
|
Test motor functionality, replace motor/bearings if needed
|
Completed
|
|
Inspect internal pump seals, replace if needed
|
Completed
|
|
Inspect all internal hoses for leaks, ensure clean seals
|
Completed
|
|
Confirm unit achieves specified temperature ranges
|
Completed
|
|
Verify unit reaches specified vacuum levels
|
Completed
|
|
Conduct a 6-8 hour cycle test for operational performance
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|