Home > Chromatography - HPLC
Need help selecting a product? Use our new filter tool to help you find the right product.
Sort By:
Page of 11
Agilent 1200 HPLC System w/ DAD Agilent 1200 HPLC System w/ DAD

Recertified Agilent 1200 System
Included with the Agilent 1200 HPLC System w/ DAD:
Includes:

> G1311A Quaternary Pump
> G1329A Thermal Autosampler
> G1330B Thermal Unit
> G1315C DAD Detector
> G1316A TCC
> G1322A Degasser
> Windows 10 Professional 64-Bit Data Station with Flatscreen Monitor
> Chemstation version 4.3 Software installed
> All Power Cords
> Can/Crossover Cables
> Agilent G1369 Lan Interface Card
> Solvent Tubing
> Capillaries
> All Performance Reports and 4 Peak Report
> Full 180 Day Parts and Labor Warranty

Our Price: $22,895.00
Deal of the Month Price: $21,995.00
Money Saved: $900.00
2 in stock!
Agilent 1260 Infinity I HPLC System w/ DAD Agilent 1260 Infinity I HPLC System w/ DAD

Agilent 1260 Infinity HPLC System w/ DAD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 to 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 x 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 x 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 to 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cells

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC

Our Price: $52,795.00
Sale Price: $41,995.00
Money Saved: $10,800.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD

Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 to 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 × 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 × 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 to 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cell

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC

FLD Detector

Specification

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

Single wavelength operation: ‚ RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell ‚ RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h

Pulse frequency

296 Hz for single signal mode 74 Hz for economy mode

Excitation Monochromator

Range: settable 200 nm to 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: settable 200 nm to 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Reference System

In-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200 ‚ 400 nm, 10 nm step) Step size: 1 to 20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Our Price: $54,495.00
Sale Price: $47,995.00
Money Saved: $6,500.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ DAD & FLD Agilent 1260 Infinity I HPLC System w/ DAD & FLD

Agilent 1260 Infinity I HPLC System w/ DAD & FLD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 to 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 x 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 x 10^-3 AU/hr at 254 nm
Linear Absorbance Range > 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 to 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cell Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC
FLD Detector

Specification

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

Single wavelength operation: RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell ‚ RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h

Pulse frequency

296 Hz for single signal mode 74 Hz for economy mode

Excitation Monochromator

Range: settable 200 nm to 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: settable 200 nm to 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Reference System

In-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200 ‚ 400 nm, 10 nm step) Step size: 1 to 20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Our Price: $53,595.00
Sale Price: $45,995.00
Money Saved: $7,600.00
1 in stock!
Agilent 1260 Infinity II LC System w/ Vialsampler & DAD Agilent 1260 Infinity II LC System w/ Vialsampler & DAD

Agilent 1260 Infinity II LC System w/ Vialsampler & DAD Specifications

DAD Detector Specification

Detection Type

1024-element photodiode array
Light Source Deuterium lamp
Number of Signals 8
Maximum Sampling Rate 240 Hz (both spectra and signals)
Wavelength Range 190 - 950 nm
Short Term Noise

With 10 mm Max-Light cartridge cell: < ± 3 x 10-6 AU at 230/4 nm, slit width 4 nm, TC 2 s , ASTM

With 60 mm Max-Light cartridge cell (included): < ± 0.6 x 10-6 AU at 230/4 nm, slit width 4 nm, TC 2 s , ASTM

Drift < 0.5 x 10-3 AU/h at 230 nm
Linearity > 2.0 AU (5%) at 265 nm, typically 2.5 AU (5%)
Wavelength Accuracy ± 1 nm
Wavelength Bunching 2 - 400 nm in steps of 1 nm
Wavelength Precision < ± 0.1 nm
Slit Width 1, 2, 4, 8 nm
Diode Width ~0.5 nm
Flow Cell Max-Light cartridge cell (high sensitivity): 60 mm
Spectral Tools Data analysis software for spectra evaluation, including spectral libraries and peak purity functions

Our Price: $54,995.00
Sale Price: $47,395.00
Money Saved: $7,600.00
1 in stock!
Agilent 1260 Infinity II LC System w/ Vialsampler & VWD Agilent 1260 Infinity II LC System w/ Vialsampler & VWD

Agilent 1260 Infinity II LC System w/ Vialsampler & VWD Specifications

VWD Detector Specification

Detection Type

Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Noise

< ± 0.25 x 10^-5 AU, at 230 nm (single wavelength detection)

< ± 0.80 x 10^-5 AU, at 230 nm and 254 nm (dual wavelength detection)

Drift < 1 x 10^-4 AU/h at 230 nm
Linearity > 2.5 AU upper limit
Wavelength Accuracy ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Wavelength Precision < ± 0.1 nm
Slit Width 6.5nm typical over whole wavelength range
Time Programmable Wavelength, polarity, peak width, lamp on/off
Flow Cell Standard: 14 µl volume, 10 mm cell path length and 40 bar (588 psi) pressure maximum
Spectral Tools Stop-flow wavelength scan

Our Price: $54,995.00
Sale Price: $44,395.00
Money Saved: $10,600.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ VWD Agilent 1260 Infinity I HPLC System w/ VWD

Agilent 1260 Infinity HPLC System w/ VWD Specifications

VWD Detector Specification
Detection Type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.5 x 10^-5 AU at 254 nm
Drift 3 x 10^-4 AU/hr at 254 nm
Linearity
> 2.0 AU (5%) upper limit
Band Width 6.5 nm typical
Maximum Data Rate 55 Hz
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cells

Standard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC
Analog Outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN

Safety and Maintenance

Extensive diagnostics, error detection, and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP Features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

Housing All materials recyclable

Our Price: $41,995.00
Sale Price: $35,995.00
Money Saved: $6,000.00
1 in stock!