Popular Alternative Choice
Accuris MR9600 SmartReader 96 Microplate Absorbance Reader
Go to Product Details
Free Shipping!
Biotek PowerWave XS Microplate Reader
Wavelength Range 200 to 999 nm
Wavelength Accuracy ± 2 nm
Absorbance Range 0.000 to 4.000 OD
- Utilizes a xenon flash lamp and monochromator for precise wavelength selection, offering superior absorbance.
- Variable Read Modes: Endpoint, kinetic, multiwavelength, and spectral scanning, adaptable for different assay requirements.
- Unique 4-Zone temperature control from 4°C above ambient to 50°C.
- Programmable microplate shaker offers low, medium, high, and variable speeds with adjustable durations for thorough sample mixing.
- Ideal for ELISA assays, kinetic enzyme assays, nucleic acid quantitation, protein analysis, and more.
- Wavelength scanning without an interference filter requirement.
The Biotek PowerWave XS is a single-channel, automated, benchtop, and general-purpose absorbance microplate reader that performs optical density measurements of samples in a 6-, 12-, 24-, 48-, 96- or 384-well microplate format. The PowerWave XS features a monochromator which offers continuous wavelength selection from 200 to 999 nm in 1-nm increments, as well as wavelength scanning without the need for interference filters. A variety of read methods can be utilized, including endpoint, kinetic, multiwavelength, and spectral scanning. This microplate reader also offers superior absorbance optical specifications, with an extended dynamic range of up to 4.000 OD. The user may choose from three reading speeds: normal, rapid, and the ultra fast sweep mode. The microplate reader is computer controlled using Biotek's Gen5 PC software for all operations, including data reduction and analysis. Absorbance measurements are made by utilizing the featured xenon flash lamp and the monochromator for wavelength selection.
The PowerWave XS is also equipped a unique 4-Zone temperature control from 4°C over ambient to 50°C that ensures superior temperature uniformity necessary for kinetic assays. An internal microplate shaker is also featured on this unit, which allows for selection between low, medium, high, and variable speeds with adjustable durations all programmable by the user. The PowerWave XS can also be interfaced with Biotek's BioStack Microplate Stacker for robotic functionality. Common applications this microplate reader is used for includes: ELISA assays, kinetic enzyme assays, nucleic acid quantitation, protein analysis, and much more.
The Biotek PowerWave XS Microplate Reader includes:
- > Windows 11 Professional 64-Bit Data Station with Pre-Loaded Gen5 PC Software
- > ABS and Self Test Calibration Report
- > Operator's Manual
- > Interface Cable
- > Full 180 Day Part and Labor Warranty
Biotek PowerWave XS Microplate Reader Specifications
Wavelength Range
|
200 to 999 nm
|
Wavelength Accuracy
|
± 2 nm
|
Wavelength Repeatability
|
± 0.2 nm
|
Wavelength Bandpass
|
2.4 nm
|
Microplate Capacity
|
Standard 6-, 12-, 24-, 48-, 96- and 384-well microplates
|
Dimensions (L x W x H)
|
8.5 x 8.5 x 16 in (21.6 x 21.6 x 40.6 cm)
|
Weight
|
24 lb. (11 kg)
|
Environment
|
Operational temperature 15º to 35°C
|
Light Source
|
Xenon flash light source: 10 W max. average power, Life: 1 billion flashes
|
Humidity
|
10% to 85% relative humidity (non-condensing)
|
Power Consumption
|
100 VA max
|
Incubation
|
Temperature control range from Ambient +4º to 50ºC
Temperature variation ± 0.50°C across the plate @ 37°C (250 µL per well with the plate sealed)
|
Plate Shaking
|
User programmable with control for intensity and time, with low, medium and high frequencies
|
Read Modes
|
Normal, Rapid and Sweep
|
Absorbance Measurement Range
|
0.000 to 4.000 OD
|
Absorbance Accuracy
|
2.000 to 2.500 OD ± 3.0% ± 0.010 OD Normal and Rapid modes, 96- and 384-well plates
0.000 to 1.000 OD ± 1% ± 0.010 OD Sweep mode, 96- and 384-well plates
|
Absorbance Linearity
|
2.000 to 2.500 OD ± 3.0% Normal and Rapid modes, 96- and 384-well plates
0.000 to 1.000 OD ± 1% Sweep mode, 96- and 384-well plates
|
Absorbance Repeatability
|
2.000 to 2.500 OD ± 3.0% ± 0.005 OD Normal and Rapid modes, 96- and 384-well plates
0.000 to 1.000 OD ± 2% ± 0.010 OD Sweep mode, 96- and 384-well plates
|
Electrical Requirements
|
100-240V, 50-60Hz
|
Computer Specifications
|
Processor
|
Intel Core I5-8350U CPU
|
RAM
|
16.0 GB
|
Hard Drive
|
512GB Internal SSD
|
Operating System
|
Windows 11 Professional, 64-bit
|
Click Here to View the Technical Specs for the BioTek PowerWave XS Reader
- Confirm the power supply and PCB output correct, stable voltages across all required connections
- Inspect the display for any dim or dead pixels; replace affected components to maintain full visual clarity and operational accuracy
- Verify full functionality of all buttons, ensuring precise and responsive input control
- Check the XY assembly for proper movement and alignment; thoroughly clean all railings, removing any debris or contaminants
- Confirm stable software communication and connection between the instrument and PC, addressing any connectivity issues
- Inspect and clean or replace all filters as required to ensure optimal airflow and performance
- Examine internal wiring and electrical connections for any breaks, disconnections, or tears; replace or secure any compromised wiring
- Test the lamp’s full functionality, replacing it if any performance issues, dimming, or faults are detected
- Execute the necessary validation protocol, documenting completion with a date on a calibration/verification certificate
- Perform and verify appropriate updates to the PC operating system for compatibility and security
- Conduct a thorough cosmetic inspection, ensuring all external components meet quality and aesthetic standards
Technician Inspection and Recertification Checklist: Instruments
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Confirm stable, correct voltage outputs from power supply and PCB
|
Completed
|
|
Inspect display for dim or dead pixels; replace as needed
|
Completed
|
|
Verify functionality of all buttons for precise, responsive control
|
Completed
|
|
Check XY assembly for proper movement; clean railings to remove debris
|
Completed
|
|
Confirm stable software communication between instrument and PC
|
Completed
|
|
Inspect and clean or replace filters to maintain optimal performance
|
Completed
|
|
Examine internal wiring for damage; replace or secure compromised connections
|
Completed
|
|
Test lamp functionality; replace if dimming or faults are detected
|
Completed
|
|
Execute validation protocol and document on calibration/verification certificate
|
Completed
|
|
Update PC operating system for compatibility and security
|
Completed
|
|
Conduct cosmetic inspection to ensure quality of external components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|