Biotek PowerWave HT 340 Microplate Reader
The Biotek PowerWave HT 340
is an eight-channel, automated, benchtop, and general-purpose absorbance microplate reader that performs optical density measurements of samples in a 96- or 384-well microplate format. The PowerWave HT 340 features a monochromator which offers continuous wavelength selection from 340 to 999 nm in 1-nm increments, as well as wavelength scanning without the need for interference filters. A variety of read methods can be utilized, including endpoint, kinetic, multiwavelength, and spectral scanning. The user may choose from three reading speeds: normal, rapid, and sweep mode. The microplate reader is computer controlled using Biotek's Gen5 PC software for all operations, including data reduction and analysis.
Absorbance measurements are made by utilizing the featured xenon flash lamp and the monochromator for wavelength selection.
The PowerWave HT 340 is also equipped a unique 4-Zone temperature control from 4°C over ambient to 50°C that ensures superior temperature uniformity necessary for kinetic assays. An internal microplate shaker is also featured on this unit, which allows for selection between low, medium, high, and variable speeds with adjustable durations. The PowerWave HT 340 can also be interfaced with Biotek's BioStack Microplate Stacker for robotic functionality.
The Biotek PowerWave HT 340 Microplate Reader includes:
- > Windows 11 Professional 64-Bit Data Station with Pre-Loaded Gen5 PC Software
- > ABS and Self Test Calibration Report
- > Operator's Manual
- > Interface Cable
- > Full 180 Day Part and Labor Warranty
Biotek PowerWave HT 340 Microplate Reader Specifications
Wavelength Range
|
340 to 999nm
|
Wavelength Accuracy
|
± 2 nm
|
Wavelength
Repeatability
|
± 0.2 nm
|
Wavelength Bandpass
|
5 nm
|
Microplate Capacity
|
Standard 96- and
384-well microplates
|
Dimensions (D x W x
H)
|
16 x 8.5 x 8.5 in
(40.6 x 21.6 x 21.6 cm)
|
Weight
|
24 lb. (10.9 kg)
|
Environment
|
Operational
temperature 18º to 40°C
|
Light Source
|
Absorbance: Xenon
flash light source
|
Humidity
|
10% to 85% relative
humidity (non-condensing)
|
Power Consumption
|
100 VA max
|
Incubation
|
Temperature control
range from 4º over ambient to 50ºC
Temperature
variation ± 0.50°C across the plate @ 37°C (250 µL per well with the plate
sealed)
|
Plate Shaking
|
Low, Medium, High
and Variable shaking speeds. Duration is programmable by the user
|
Read Modes
|
Normal, Rapid and
Sweep
|
Absorbance
Measurement Range
|
0.000 to 4.000 OD
|
Absorbance Accuracy
|
2.000 to 2.500 OD ±
3.0% ± 0.010 OD Normal and Rapid modes, 96- and 384-well plates
|
Absorbance Linearity
|
2.000 to 2.500 OD ±
3.0% Normal and Rapid modes, 96- and 384-well plates
|
Absorbance
Repeatability
|
2.000 to 2.500 OD ±
3.0% ± 0.005 OD Normal and Rapid modes, 96- and 384-well plates
|
Computer Specifications
|
Processor
|
Intel Core I5-8350U CPU
|
RAM
|
16.0 GB
|
Hard Drive
|
512GB Internal SSD
|
Operating System
|
Windows 11 Professional, 64-bit
|
Biotek PowerWave HT 340 Microplate Reader Manual
Click Here to View the Technical Specs for the Biotek PowerWave HT 340
Frequently Purchased With
- Confirm the power supply and PCB output correct, stable voltages across all required connections
- Inspect the display for any dim or dead pixels; replace affected components to maintain full visual clarity and operational accuracy
- Verify full functionality of all buttons, ensuring precise and responsive input control
- Check the XY assembly for proper movement and alignment; thoroughly clean all railings, removing any debris or contaminants
- Confirm stable software communication and connection between the instrument and PC, addressing any connectivity issues
- Inspect and clean or replace all filters as required to ensure optimal airflow and performance
- Examine internal wiring and electrical connections for any breaks, disconnections, or tears; replace or secure any compromised wiring
- Test the lamp’s full functionality, replacing it if any performance issues, dimming, or faults are detected
- Execute the necessary validation protocol, documenting completion with a date on a calibration/verification certificate
- Perform and verify appropriate updates to the PC operating system for compatibility and security
- Conduct a thorough cosmetic inspection, ensuring all external components meet quality and aesthetic standards
Technician Inspection and Recertification Checklist: Instruments
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Confirm stable, correct voltage outputs from power supply and PCB
|
Completed
|
|
Inspect display for dim or dead pixels; replace as needed
|
Completed
|
|
Verify functionality of all buttons for precise, responsive control
|
Completed
|
|
Check XY assembly for proper movement; clean railings to remove debris
|
Completed
|
|
Confirm stable software communication between instrument and PC
|
Completed
|
|
Inspect and clean or replace filters to maintain optimal performance
|
Completed
|
|
Examine internal wiring for damage; replace or secure compromised connections
|
Completed
|
|
Test lamp functionality; replace if dimming or faults are detected
|
Completed
|
|
Execute validation protocol and document on calibration/verification certificate
|
Completed
|
|
Update PC operating system for compatibility and security
|
Completed
|
|
Conduct cosmetic inspection to ensure quality of external components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
 |
 |
 |
 |

|