BioTek 405 TSUVS Microplate Washer
The BioTek 405 TSUVS Microplate Washer incorporates a high-resolution touch screen user interface for intuitive and flexible onboard instrument control of 96- and 384-well microplate washing. The 5.7 inch graphical color display and onboard software guides users through protocol development, instrument maintenance, and daily use at the touch of a finger. The 405 TSUVS has a unique set of features designed to efficiently wash cell-based assays, microsphere-based assays, and ELISA applications. This model specifically includes the following features: cell washing, wash buffer switching, ultrasonic advantage, and automated magnetic bead assays. The patented Verify technology integrated into this washer automatically checks for manifold tube blockages before a wash cycle, and the ultrasonic advantage automatically cleans any blocked manifold tubes. These functions save time and eliminate frustration while ensuring successful results. All of our equipment is fully tested to perform at factory specifications before being shipped.
The BioTek 405 TSUVS Microplate Washer includes:
- > (2) 4 Liter Waste Bottles
- > (4) 4 Liter Buffer Bottles
- > Vacuum Pump
- > Stainless Steel Bottle Holders
- > Microplate Carrier
- > Vacuum Tubing with Connections
- > Power Cord
- > Operator’s Manual
- > Full 180 Day Parts and Labor Warranty
BioTek 405 TSUVS Microplate Washer Specifications
Microplate Types
|
96- and 384-well
Low profile and standard height
|
Manifold Type
|
Dual-Action 96-tube (8x12) for 96-/384-well washing
|
Volume Range
|
25 to 3,000 µL/well
|
Buffer Selection
|
Automated internal switching of up to 4 wash buffers
|
Flow Rates
|
1 to 11, slow to fast, including low flow cell wash rates
|
Wash Cycles
|
1 to 250
|
Dispense Precision
|
≤ 3% CV
|
Residual Volume
|
≤ 2 µL/well (solid bottom plates)
|
Shaking
|
Programmable in min/sec, up to 60 minutes with slow, medium, or fast intensities
|
Soak Time
|
Programmable in min/sec, up to 60 minutes
|
Wash Speed
|
96-well: 3 cycles, 300 µL/well, 96-tube manifold, final aspirate: ≤ 30 seconds
384-well: 3 cycles, 100 µL/well, 96-tube manifold, final aspirate: ≤ 80 seconds
|
User Interface
|
High resolution 5.7" touch screen with color graphical display
|
Onboard Software
|
Intel Atom processor running Windows CE
|
Dimensions (D x W x H)
|
17 x 14 x 10 in. (43.2 x 35.6 x 25.4 cm)
|
Weight
|
36 lb. (16.5 kg.)
|
Electrical Requirements
|
100-240V, 50/60Hz
|
Click Here to Expand The 405 TS Series Model Comparison
BioTek 405 TS Series Model Comparison
Model
|
384-Well
|
96-Well
|
Cell Washing
|
4-Buffer Switching
|
Ultrasonic Advantage
|
Verify Technology
|
Biomagnetic Separation
|
Vacuum Filtration
|
405TSHT
|
x
|
|
|
|
|
|
x
|
x
|
405TSHTV
|
x
|
|
|
x
|
x
|
|
x
|
x
|
405TSU
|
x
|
x
|
x
|
|
|
|
x
|
x
|
405TSUV
|
x
|
x
|
x
|
x
|
|
|
x
|
x
|
405TSUS
|
x
|
x
|
x
|
|
x
|
|
x
|
x
|
405TSUSQ
|
x
|
x
|
x
|
|
x
|
x
|
x
|
x
|
405TSUVS
|
x
|
x
|
x
|
x
|
x
|
|
x
|
x
|
405TSUVSQ
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
405TSR
|
|
x
|
|
|
|
|
x
|
x
|
405TSRV
|
|
x
|
|
x
|
|
|
x
|
x
|
405TSRS
|
|
x
|
|
|
x
|
|
x
|
x
|
405TSRSQ
|
|
x
|
|
|
x
|
x
|
x
|
x
|
405TSRVS
|
|
x
|
|
x
|
x
|
|
x
|
x
|
405TSRVSQ
|
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
- Install new waste and buffer bottles to ensure proper fluid containment and system functionality.
- Integrate a new pump into the system, verifying compatibility and secure connections.
- Verify that the power supply and PCB output the correct voltages for reliable component operation.
- Conduct a self-test on the microplate washer, evaluating all operational parameters.
- Inspect the X-axis motor belt for signs of wear, such as tears, frays, or breakages, replacing if necessary.
- Examine dispense and aspirate tubes for any damage that could affect fluid flow accuracy.
- Confirm internal pump functionality, replacing seals as needed to maintain optimal performance.
- Inspect all internal wiring for frays, tears, or breakages, addressing any faults for electrical safety.
- Verify functionality of all internal and external sensors, ensuring accurate readings across the unit.
- Disinfect the unit using an appropriate disinfection cycle to ensure sterility and safety.
- Check that residual aspiration levels are within the manufacturer’s specified limits for accuracy.
- Conduct a final cosmetic inspection to verify that all external surfaces meet appearance standards.
Technician Inspection and Recertification Checklist: Microplate Washer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task |
Completed? |
Remarks? |
Install new waste and buffer bottles | Completed | |
Integrate new pump into system, verifying secure connections | Completed | |
Verify power supply and PCB output correct voltages | Completed | |
Conduct microplate washer self-test and evaluate results | Completed | |
Inspect X-axis motor belt for wear, replacing if necessary | Completed | |
Examine dispense and aspirate tubes for any damage | Completed | |
Confirm internal pump functionality, replace seals as needed | Completed | |
Inspect internal wiring for frays, tears, or breakages | Completed | |
Verify functionality of all internal and external sensors | Completed | |
Disinfect unit with appropriate disinfection cycle | Completed | |
Check residual aspiration levels meet specifications | Completed | |
Conduct cosmetic inspection for appearance standards | Completed | |
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|