Benchmark Incu-Shaker 10LR Refrigerated Incubator Shaker
The Benchmark Incu-Shaker 10LR Refrigerated Incubator Shaker is a heavy-duty performer, designed for heavy workloads and continuous use. Its outstanding temperature accuracy and uniformity are supported by proprietary heat distribution technology that ensures that temperatures are precisely maintained throughout the chamber. Inconsistencies due to stratification are reduced to negligible levels and the selected temperature is precisely maintained within 0.25%, even in the corners. The powerful brushless induction drive is designed for years of trouble-free service, even under continuous use conditions with heavy loads. Noise and vibration are minimized by an advanced, computer-designed motor isolation system. The convenient MAGic Clamp platform is also included for use with Erlenmeyer flasks and test tube racks. The unique, magnetic attachment method is the easiest way to instantly change between flask clamps of different sizes.
All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Benchmark Incu-Shaker 10LR Refrigerated Incubator Shaker includes:
- > 18" x 18" MAGic Clamp Large Universal Platform
- > 1 x MAGic Clamp COMBO Flask Clamp, for 125ml, 250ml, 500ml
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Benchmark Incu-Shaker 10LR Refrigerated Incubator Shaker Specifications
Speed Range
|
30 to 300 RPM
|
Speed Control Increment
|
± 1 RPM
|
Temperature Range
|
Ambient -12°C to 60°C
|
Temperature Uniformity
|
± 1.25°C
|
Temperature Accuracy
|
± 0.1°C
|
Temperature Control Increments
|
± 0.1°C
|
Timer
|
1 minute to 48 hours, or continuous
|
Orbit Size
|
1.9 cm (0.75 in)
|
Platform Size
|
18 x 18 in. (45.7 x 45.7 cm)
|
Chamber Dimensions (W x D x H)
|
19.5 x 19.5 x 11 in. (49.5 x 49.5 x 28 cm)
|
Overall Dimensions (W x D x H)
|
20 x 31 x 22 in. (51 x 79 x 56 cm)
|
Weight
|
170 lb. (77 kg)
|
Electrical Requirements
|
115V, 50/60Hz, 1200W
|
- Examine the chamber glass for cracks or chips, replacing it as needed to maintain structural integrity.
- Inspect door seals for signs of wear or damage, replacing them to ensure a tight seal.
- Check the display for brightness and clarity, replacing any dim or dead pixels to maintain optimal visibility.
- Test all buttons to confirm full functionality and consistent responsiveness.
- Replace all platform assembly bearings to ensure smooth and reliable motion.
- Inspect the drive belt for wear, replacing it if torn or cracked to maintain performance.
- Examine all wiring for frays, tears, or breakages, addressing any issues for electrical safety.
- Verify each PCB test point, replacing any malfunctioning components to ensure system reliability.
- Check drive belt tension to confirm correct alignment and function.
- Confirm the compressor’s operation, cleaning condenser filter and fins for efficient cooling.
- Calibrate internal temperature accuracy using an NIST-traceable temperature probe.
- Measure and calibrate platform RPMs with an NIST-traceable tachometer to ensure precision.
- Conduct a final cosmetic inspection to verify all surfaces meet appearance standards.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task |
Completed? |
Remarks? |
Examine chamber glass for cracks or chips, replace as needed | Completed | |
Inspect door seals for wear, replace to ensure tight seal | Completed | |
Check display brightness, replace dim or dead pixels | Completed | |
Test all buttons for full functionality and responsiveness | Completed | |
Replace platform assembly bearings for reliable motion | Completed | |
Inspect drive belt for wear, replace if torn or cracked | Completed | |
Examine wiring for frays or breakages, repair as needed | Completed | |
Verify PCB test points, replace faulty components | Completed | |
Check drive belt tension for proper alignment | Completed | |
Confirm compressor functionality, clean filter and fins | Completed | |
Calibrate internal temperature with NIST probe | Completed | |
Calibrate platform RPM with NIST-traceable tachometer | Completed | |
Conduct cosmetic inspection for appearance standards | Completed | |
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|