4.8
Customer Reviews
Skip to content
To take full advantage of this site, please enable your browser's JavaScript feature.
Learn how
You're Viewing Our Recertified Equipment
|
Click Here to Switch to Our New Equipment
What's included
Specs
Testimonials
Recert Protocol
MarshallCare™
Add to Cart
Request A Formal Quote
About Us
My Account
My Cart
(603) 601-8511
www.MarshallScientific.com
Menu
Specials
Home
Categories
Services
Equipment Repair Request Form
Lab Equipment
Return and Refund Policy
RPM to RCF Calculator
Cannabis Testing Equipment
Rotor Compatibility Guide
View New Equipment
Contact Us
603-601-8511
About Us
Sustainability
Our Team
Testimonials
Careers
Sell Equipment
Lab Liquidation
Financing
Startup Packages
My Account
Most Products Ship Fast & Free!
Equip Yourself Sooner:
View Details
Need Instrument Repair Services?
Fast & Cost-Effective Solutions Available:
Contact Us
Take Advantage of our Acclaimed Chat Support Today!
Always Powered by Humans:
Start Chatting
Equipment Categories
Analyzers
Aspirators
Autoclaves
Balances
Cell Counters
Cell Disruptors
Centrifuges
Centrifuge Rotors
Centrifuge Adapters
Rotor Buckets
Chromatography - HPLC
HPLC Systems
HPLC Components
Chromatography - FPLC
FPLC Systems
FPLC Components
Circulating Chillers
Chiller Pumps
Cytometers
Dry Bath Heaters
Electrophoresis Power Supplies
Evaporators - Blowdown
Evaporators - Centrifugal
Cold Traps
Evaporator Rotors
Evaporators - Rotary
Diaphragm Vacuum Pumps
Evaporating Systems
Heating Baths
Vacuum Controllers
Freeze Dryer Systems
Freeze Dryer Accessories
Freezers
Glassware Washers
Heated Circulators
Histology
Centrifuges
Microscopes
Microtomes
Slide Stainers
Slide Warmers
Homogenizers
Dismembrators & Sonifiers
Hot Plates Stirrers
Imaging Systems
Incubators
Incubator Shakers
Lab Refrigerators
Lab Furniture
Mass Spectrometry
Microplate Readers
Microplate Washers
Microscopes
Mixers
New Arrivals
Ovens
Ozone Generators
Peristaltic Pumps
Pipettes
Shakers
Spectrophotometers
Thermal Cyclers / PCR
Thermal Cycler Blocks
Real-Time PCR Systems
Thermal Mixers
Ultrasonic Cleaners
Vacuum Concentrators
Vacuum Pumps
Vortexers
Water Baths
Home
>
Spectrophotometers
>
Agilent G1120A Multicell Transport for 8453 & 8454 Spectrophotometers
Net 30 Terms and Financing Available
Our Price
:
$
795.00
Condition:
Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty:
180-Day Full Parts and Labor (Click for Info)
Typically Ships Within:
1 to 2 Business Days
Request a Formal Quote
Quantity in Stock:1
Product Code:
AG-G1120A
Qty:
Description
Recertification Protocol
Technical Specification Sheet
Agilent G1120A Multicell Transport for 8453 & 8454 Spectrophotometers
The Agilent G1120A Multicell Transport is an accessory for the Agilent 8453 and 8454 UV-Visible Spectrophotometers. The multicell transport cell holder holds eight cells in a rack which can be held at a constant temperature with water circulated from a thermostatic bath (provided by the user). The holder is attached to the multicell transport base which contains a stepper motor to move the designated cell into the optical path. A water-driven magnetic stirrer (not included) can be fitted under the holder in one of two positions, either under the cell in the optical path, or under the cell to the left of the cell in the optical path.
The outside dimensions of individual cells must be 12.5 × 12.5 mm and the height from base of the cell to the sample area 15 mm. During an analysis, the position of individual cells is maintained by a flat spring inside each of the cell compartments. The spring alone fixes the cell and no additional fixing mechanism is needed. The Agilent G1120A Multicell Transport for 8453 and 8454 Spectrophotometers can be controlled by any Agilent Technologies UV-visible operating software, having revision A.05.xx or higher, through the accessory interface of the spectrophotometer.
Please Note: The Agilent G1120A Multicell Transport is not compatible with older Hewlett-Packard Spectrophotometers such as the HP 8450, HP 8451, and HP 8452A.
All of our equipment is fully tested to perform at factory specifications before being shipped.
INCLUDED:
The Agilent G1120A Multicell Transport for 8453 & 8454 Spectrophotometers includes:
>
Eight-Position Cell Holder
>
Operator's Manual
>
Full 180 Day Part and Labor Warranty
Agilent G1120A Multicell Transport for 8453 & 8454 Spectrophotometers Specifications
Time to Move Between Adjacent Cell Positions
< 1 second
Position Repeatability
± 0.1 mm
Step Resolution
0.060 mm
Temperature Range for Thermostatting (Cell Holder Only)
5 to 90°C
Temperature Difference Between any Two Cell Positions
0.3°C (with a water bath at 37°C)
Downloads
Technical Specification Download
Operator's Manual Download
Request a Formal Quote
Instrument Inspection and Recertification Checklist
Confirm the power supply and PCB output correct, stable voltages across all required connections
Inspect the display for any dim or dead pixels; replace affected components to maintain full visual clarity and operational accuracy
Verify full functionality of all buttons, ensuring precise and responsive input control
Check the XY assembly for proper movement and alignment; thoroughly clean all railings, removing any debris or contaminants
Confirm stable software communication and connection between the instrument and PC, addressing any connectivity issues
Inspect and clean or replace all filters as required to ensure optimal airflow and performance
Examine internal wiring and electrical connections for any breaks, disconnections, or tears; replace or secure any compromised wiring
Test the lamp’s full functionality, replacing it if any performance issues, dimming, or faults are detected
Execute the necessary validation protocol, documenting completion with a date on a calibration/verification certificate
Perform and verify appropriate updates to the PC operating system for compatibility and security
Conduct a thorough cosmetic inspection, ensuring all external components meet quality and aesthetic standards
Technician Inspection and Recertification Checklist: Instruments
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
Completed?
Remarks?
Confirm stable, correct voltage outputs from power supply and PCB
Completed
Inspect display for dim or dead pixels; replace as needed
Completed
Verify functionality of all buttons for precise, responsive control
Completed
Check XY assembly for proper movement; clean railings to remove debris
Completed
Confirm stable software communication between instrument and PC
Completed
Inspect and clean or replace filters to maintain optimal performance
Completed
Examine internal wiring for damage; replace or secure compromised connections
Completed
Test lamp functionality; replace if dimming or faults are detected
Completed
Execute validation protocol and document on calibration/verification certificate
Completed
Update PC operating system for compatibility and security
Completed
Conduct cosmetic inspection to ensure quality of external components
Completed
To View More of Our Recertification Protocol
Click Here
Click Here to View the Technical Specs for the Agilent G1120A Multicell Transport for 8453 & 8454 Spectrophotometers
Similar Products
Eppendorf BioPhotometer Plus Model #6132
BioTek ELx800 Microplate Reader - Absorbance Only
Molecular Devices SpectraMax 384 Plus Microplate Reader
Biotek PowerWave XS Microplate Reader
Sale Price
: $3,395.00
Sale Price
: $4,295.00
Our Price
:
$8,495.00
Sale Price
: $6,295.00
BioTek ELx808 Microplate Reader - Absorbance Only
NanoDrop ND-1000 Spectrophotometer
Molecular Devices SpectraMax Plus Microplate Reader
Thermo Scientific NanoDrop 2000c Spectrophotometer
Sale Price
: $4,195.00
Our Price
:
$5,395.00
Our Price
:
$7,695.00
Sale Price
: $7,995.00
Share your knowledge of this product.
Be the first to write a review »
Browse for more products in the same category as this item:
Spectrophotometers
Spectrophotometer Capability
Spectrophotometer Capability
>
Absorbance (UV-Vis)
Spectrophotometer Capability
>
Fluorescence
Spectrophotometer Capability
>
Luminescence
Spectrophotometer Absorbance Wavelength Range
Spectrophotometer Absorbance Wavelength Range
>
260 to 600nm
Spectrophotometer Absorbance Wavelength Range
>
200 to 800nm
Spectrophotometer Absorbance Wavelength Range
>
200 to 1,000nm
Spectrophotometer Absorbance Wavelength Range
>
190 to 1,100nm
Spectrophotometer Absorbance Wavelength Range
>
320 to 1,100nm
Brand
Brand
>
Agilent