Home > Mass Spectrometry >

New!  Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System
Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System
 
 



Stock Notification!

The Agilent 6130B Single Quadrupole Mass Spec w/ Agilent 1200 MS/LC System you were interested in is currently unavailable, but we have a great alternative for you!

Our Price: $67,795.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 2 Weeks
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report & Mass Spec Tuning Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-6130LCMS1260
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System



Mass Range
10 to 3,000 m/z

Mass Accuracy
± 0.13 Da

Scan Speed
10,400 Da/sec

Features
  • Features 30 msec ultrafast ion polarity switching for maximum data collection
  • Supports multiple ionization sources including ESI, APCI, APPI, and multimode options
  • Provides dynamic range exceeding 6 × 10⁶ for reliable quantitation
  • Ensures long-term stability with < 0.1 amu mass drift over 12 hours
  • High-performance detector with high gain electron multiplier horn
  • Fully controlled via Agilent ChemStation Workstation Software for streamlined operation
  • SIM sensitivity with signal-to-noise ratio > 250:1 for ESI positive mode
  • Maximum SIM dwell time of 5 msec for fast, accurate quantitation
  • Equipped with a reliable vacuum system featuring a turbo-molecular and mechanical pump

The Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System delivers unmatched analytical performance and proven day-after-day reliability from routine QC to research applications. This 6130B model is specifically a flexible, high performance solution ideal for any quantitation application with 3000 Da mass range and 1 pg sensitivity. This system allows users to rapidly screen compounds and confirm molecular weights, purify target compounds in complex mixtures, quantitate target compounds, positively identify impurities and more. The Agilent 6130B Single Quadrupole Mass Spectrometer provides unmatched sensitivity, simplifying sample preparation and LC method development. An ultrafast scan speed allows users to take full advantage of UHPLC separations, as well as featuring ultrafast ion polarity switching to return maximum information from a single injection, even with narrow LC peaks. The Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.

This turnkey Agilent LC/MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 6130B Single Quadrupole Mass Spectrometer w/ 1260 Infinity I LC System includes:
  • > Agilent 6130B Single Quadrupole Mass Spec
  • > Agilent MS40+ Rotary Vane Vacuum Pump
  • > G1948B ESI Ionization Source
  • > G1312B Binary Pump (G1311B Quaternary Pump available, please inquire)
  • > G1329B Autosampler
  • > G1330B ALS Thermostat
  • > G1316A TCC
  • > G1379B Degasser
  • > G4212B DAD Detector
  • > Windows 10 Professional 64-Bit Data Station with Flatscreen Monitor
  • > ChemStation Version 4.3 Software Installed
  • > All Power Cords
  • > Can/Crossover Cables
  • > Agilent Lan Interface Card Built-In
  • > Solvent Tubing
  • > Capillaries
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report & Mass Spec Tuning Report
  • > Full 180 Day Parts and Labor Warranty



Below is a List of Diagnostic Tests Performed On This System
G4212B Diode Array Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1312B Binary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316A Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329B Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 HPLC System.


Agilent 6130B Single Quadrupole Mass Spectrometer Specifications

Maximum Scan Speed 10,400 Da/sec
SIM Sensitivity, ESI Positive Signal-to-noise ratio > 250:1 (1 pg of reserpine injected on column,
quantifying the m/z 609 ion)
SIM Sensitivity, APCI Positive Signal-to-noise ratio > 100:1 (1 pg of reserpine injected on column,
quantifying the m/z 609 ion)
Polarity Switching 30 msec (switching time from positive to negative polarity)
Mass Resolution (Autotune) Unit resolution (full width at half maximum)
Mass Stability < 0.1 amu or 100 ppm, whichever is larger (over 12 hours)
Mass Accuracy ± 0.13 Da
Maximum SIM Dwell Time 5 msec
Maximum SIM Transitions

100 (one time segment)

Dynamic Range > 6 × 10 6
Mass Range 10–3,000 m/z
Single Point of Control Single-point data system method capability with full control of Agilent 1200 Series LC Systems and 6100 Series Single Quadrupole LC/MS Systems
Time Programming SIM ion selections, Scan functions, Fragmentor voltage, External CAN valves
Ionization Sources Electrospray (ESI), Multimode source (simultaneous ESI and APCI), Atmospheric pressure chemical ionization (APCI), ChipCube for intergrated nanoLC, Atmospheric pressure photoionization (APPI)
Detector High energy conversion dynode and high gain electron multiplier horn
Vacuum System One turbo-molecular pump with one mechanical pump
Dimensions (W x H x D) 14 x 18 x 25 in. (35 x 45 x 63.5 cm)
Weight 137.6 lb. (63.4 kg.)
Electrical Requirements 200-230VAC, 60Hz or 200-240VAC, 50Hz

Click Here to View Specifications for the Agilent 1260 Infinity I LC System

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength ± 3 × 10 -6 AU at 230 nm/4 nm
Drift < 0.5 × 10 -3 AU/hr at 230 nm
Linear Absorbance Range > 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 4 nm
Diode Width ~ 0.5 nm
Flow Cell

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Binary Pump Specification
Hydraulic System Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons
Setable Flow Range 0.001 – 5 ml/min, in 0.001 ml/min increments
Flow Range

0.5 - 5.0 mL/min

Flow Precision ≤ 0.07% RSD or ≤ 0.02 min SD, whatever is greater
Flow Accuracy ± 1% or 10 µl/min, what ever is greater
Pressure Operating Range Operating range 0 to 600 bar (0 – 7800 psi) up to 5 ml/min
Pressure Pulsation < 2 % amplitude (typically < 1.3 %), or < 0.3 MPa (3 bar), whatever is greater, at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar, 147 psi)
Compressibility Compensation User-selectable, based on mobile phase compressibility
Recommended pH Range 1.0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless stee
Gradient Formation High-pressure binary mixing
Delay Volume 600 to 800 µl, dependent on back pressure
Composition Range 0 to 100% (1 to 99% or 5 µl/min per channel, whatever is greater is recommended)
Composition Precision < 0.15% RSD or < 0.04 min SD whatever is greater
Composition Accuracy ± 0.35% absolute at 2 mL/min, at 10 MPa (100 bar)
Autosampler Specification
Injection Range 0.1 - 100 µl in 0.1 µl increments
Precision

< 0.25 % RSD of peak areas from 5 to 100 µl

< 1 % RSD of peak areas from 1 to 5 µl

Pressure Range Operating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)
Sample Viscosity Range 0.2 to 50 cp
Sample Capacity 100 × 2 mL vials in 1 tray
40 × 2 mL vials in ½ tray
15 × 6 mL vials in ½ tray (Agilent vials only)
Injection Cycle Time 50 s for draw speed 200 µL/min, ejection speed 200 µL/min, injection volume 5 µL
Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning
ALS Thermostat Specification
Temperature Range 4°C to 40°C in 1°C increments
Temperature Accuracy at Ambient Temperatures < 25°C and Humidity < 50% 3°C to +8°C at a setpoint of 4°C
Temperature Accuracy at Ambient Temperatures > 30°C and Humidity > 60% 3°C to +9°C at a setpoint of 4°C
Column Compartment Specification
Temperature Range Ambient -10°C to 80°C at flow rates up to 5 mL/min
Temperature Stability ± 0.15 °C
Temperature Accuracy ± 0.8°C (± 0.5°C with calibration)
Column Capacity Three 30 cm
Warm-Up/Cool-Down Time 5 minutes from ambient to 40°C
10 minutes from 40°C to 20°C
Dead Volume

3 µl left heat exchanger

6 µl right heat exchanger

Degasser Specification
Number of Solvent Channels 4
Maximum Flow Rate 0 - 5 mL/min per channel
Internal Volume Per Channel Typically 1 ml per channel
Materials in Contact with Solvent PTFE, PEEK
pH Range 1 - 14


Computer Specifications

Model

Dell Optiplex 7010 Desktop PC

Processor

Intel Core i5-6500 Processor 3.2GHz

RAM

16GB

Hard Drive

250GB Internal SSD

Operating System

Windows 10 Professional, 64bit

Downloads


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Mass Spectrometry
Brand
Brand > Agilent