|
Agilent 2100 Bioanalyzer G2938C
Analysis Run Time 30 to 45 min
Number of Samples Up to 12 samples/chips
- Integrates sample handling, separation, detection, and data analysis for comprehensive bioanalysis.
- Operates on both electrophoresis and flow cytometry for versatile application, maximum flexibility, and sensitivity down to pg/μL concentrations.
- Easy operation with simple steps - add sample, start chip run, and view real-time data.
- Expert software provides qualitative and quantitative digital data, processing up to 12 samples in 30 minutes with minimal sample consumption.
- Suitable uses include DNA fragment analysis, protein applications, sampling QC in gene expression, and simple flow cytometric analysis of cells
The Agilent 2100 Bioanalyzer is a microfluidics-based platform that integrates sample handling, separation, detection, and data analysis, enabling prompt and accurate sizing, quantification, and quality control. The bioanalyzer operates on two assay principles – electrophoresis and flow cytometry – offering maximum flexibility and sensitivity down to pg/μL concentration. The 2100 is an extremely easy to use analyzer; simply add the sample, start the chip run, and watch real-time data display. Agilent’s 2100 expert software provides qualitative and quantitative digital data for up to 12 samples in 30 minutes with minimal sample consumption. Specific uses of the Agilent 2100 Bioanalyzer include DNA fragment analysis, protein applications, sampling QC in gene expression, and simple flow cytometric analysis of cells. Agilent 2100’s applications consist of quality control, evaluation of integrity, concentration, and purity, and fluorescent analysis of intact cells of limited quantity.
The Agilent 2100 Bioanalyzer is fully tested to perform at factory specifications before being shipped.
The Agilent 2100 Bioanalyzer G2938C includes:
- > Windows 11 Data Station with Agilent 2100 B.02.12 SR1 Expert Software
- > Interface Cable
- > IKA Chip Shaker (Chip Priming Station & Test Chip Kit Upgrade Available)
- > Agilent 2100 Test Chip Calibration Report
- > All Power Cords
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Agilent 2100 Bioanalyzer Specifications
Analysis Run Time
|
30 to 45 min
|
Number of Samples
|
Up to 12 samples/chips
|
Sample Volume
|
1 µl
|
Sizing Range
|
50 to 7000 bp
|
Ambient Operating Temperature
|
5° to 40°C (41° to 104°F)
|
Electrical Requirements
|
100-240VAC, 50-60Hz
|
Power Consumption
|
60 VA
|
Dimensions (W x D x H)
|
162 x 412 x 290 mm (6.4 x 16.2 x 11.4 in)
|
Safety Standards: IEC, CSA, UL
|
Installation Category II, Pollution Degree 2
|
Computer Specifications
|
Processor
|
Intel Core I5-8350U CPU
|
RAM
|
16.0 GB
|
Hard Drive
|
512GB Internal SSD
|
Operating System
|
Windows 11 Professional, 64-bit
|
Agilent 2100 Operator's Guide
Click Here to View all the Technical Specs for the Agilent 2100
Agilent 2100 Bioanalyzer with Chip Priming Station
- Verify power supply functionality to ensure stable operation of all components
- Confirm precise seating and alignment of the electrode cartridge
- Detach and perform ultrasonic cleaning on electrode pin assembly
- Validate communication between analyzer and software for seamless integration
- Ensure Agilent lid opens and closes smoothly without abrasion against the casing
- Inspect internal wiring for any shorts, tears, or compromised insulation
- Check autofocus motors for full movement range and operational accuracy
- Execute comprehensive autofocus system diagnostic analysis
- Perform detailed diagnostics for electrode and diode functionality
- Complete remaining 2100 Expert diagnostic tests to verify optimal functionality
- Inspect power cords and interface cables for wear, tears, or exposed wiring
- Verify software is fully operational and compatible with the updated computer system
Technician Inspection and Recertification Checklist: Bioanalyzers
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify power supply functionality
|
Completed
|
|
Confirm electrode cartridge seating and alignment
|
Completed
|
|
Clean electrode pin assembly using ultrasonic cleaning
|
Completed
|
|
Validate communication with software
|
Completed
|
|
Confirm lid opens and closes without abrasion
|
Completed
|
|
Inspect internal wiring for damage or shorts
|
Completed
|
|
Check autofocus motor functionality
|
Completed
|
|
Run autofocus diagnostic analysis
|
Completed
|
|
Perform electrode and diode diagnostics
|
Completed
|
|
Complete all 2100 Expert diagnostic tests
|
Completed
|
|
Inspect power and interface cables for damage
|
Completed
|
|
Confirm software and computer compatibility
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|