Agilent 1290 Infinity I HPLC G4220A Binary Pump



Settable Flow Range
0.001 – 5.0 mL/min, in 0.001 mL/min increments

Flow Precision
≤ 0.07 % RSD or 0.005 min SD, whatever is greater

Flow Accuracy
± 1 % or 10 uL/min whichever is greater

Features
  • Seal wash for continued high lifetime of pump seals for buffer applications
  • Solvent selection valve for method flexibility
  • Jet Weaver for optimum mixing performance with a minimum of delay volume
  • Automatic purge function for ease of use and unattended preparation of the system
  • Solvent selection for optimum flow and composition accuracy
  • Fast defill function for improved intake and delivery performance
  • Two pistons in series design for increased reliability
  • High resolution piston movement control for smooth and reliable motion
The Agilent 1290 Infinity I HPLC G4220A Binary Pump is expertly crafted to deliver exceptional performance and reliability for high-pressure liquid chromatography workflows. Featuring a two-channel, dual-piston in-series design with a proprietary servo-controlled variable stroke, it offers a settable flow range of 0.001–5.0 mL/min in precise 0.001 mL/min increments. With flow precision of ≤0.07% RSD and flow accuracy of ±1%, this pump provides unmatched accuracy for demanding analytical applications. It supports pressures up to 120 MPa (1200 bar) at 2 mL/min or 80 MPa (800 bar) at 5 mL/min, enabling high-throughput methods and efficient gradient formation. The high-pressure binary mixing system, coupled with the Jet Weaver for optimal mixing, ensures minimal delay volumes (<45 uL) while maintaining stability and efficiency.

Equipped with advanced features, including a two-channel integrated degassing unit with a 1.5 mL internal volume per channel, the pump ensures stable flow and enhanced detector sensitivity. Additional functionality, such as the solvent selection valve, automatic purge function, seal wash for pump longevity, and fast defill capabilities, optimizes usability and operational reliability. With updated dimensions of 9.3 × 13.5 × 17 inches and a weight of 48 pounds, the pump’s compact and robust design suits diverse laboratory setups. Researchers seeking precision, versatility, and dependability will find this pump an excellent addition to their laboratory.

All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 1290 Infinity I HPLC G4220A Binary Pump includes:
  • > Firmware version 07.02 (Can be changed upon request)
  • > Front Cover
  • > Leak and Pressure Diagnostic Report
  • > Lan Cable / Power Cord
  • > Operator's Manual
  • > Full 180 Day Parts and Labor Warranty

Agilent 1290 Infinity I HPLC G4220A Binary Pump Specifications

Hydraulic System Two dual-piston in-series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, and smooth motion control of pistons for active damping
Settable Flow Range 0.001 to 5.0 mL/min, in 0.001 mL/min increments
Flow Precision ≤ 0.07 % RSD or 0.005 min SD, whatever is greater (0.2 to 5.0 mL/min)
Flow Accuracy ± 1 % or 10 uL/min, whichever is greater. Pumping degassed H2O at 10 MPa (100 bar)
Pressure Operating Range Up to 120 MPa (1200 bar) at up to 2 mL/min; 80 MPa (800 bar) at 5 mL/min
Pressure Pulsation < 1 % amplitude or < 0.5 MPa (5 bar), whichever is greater
Compressibility Compensation Automatic, pre-defined, based on mobile phase selection
Gradient Formation High-pressure binary mixing
Delay Volume Jet Weaver V35: <45 uL; Jet Weaver V100: <75 uL. For lowest delay volumes, the Jet Weaver can be removed
Settable Composition Range Settable range: 0 to 100 %; 1 – 99 % or 5 ul/min per channel, whichever is greater
Composition Precision < 0.15 % RSD or 0.01 min SD, whatever is greater
Composition Accuracy ± 0.35 % absolute (5 to 95 %, 0.2 to 5.0 mL/min)
Solvent Selection Valve Included as a standard part of the pump
Integrated Degassing Unit Number of channels: 2; Internal volume per channel: 1.5 mL
Dimensions (H × W × D) 9.3 x 13.5 x 17 in. (24 × 34.5 × 43.5 cm)
Weight 48 lb. (21.8 kg)
Electrical Requirements 100 to 240 V, 50/60 Hz, 90 VA