Agilent 1260 Infinity II LC System
Agilent 1260 Infinity II LC System
 
 



Our Price: $59,695.00
Sale Price: $49,995.00
Money Saved: $9,700.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report

Request a Formal Quote


Quantity in Stock:



Product Code: AG-1260
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1260 Infinity II LC System


The Agilent 1260 Infinity II LC System provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar, the 1260 Infinity II Binary Pump is suitable for multiple LC applications, handling columns over the flow rate range of up to 5 ml/min. The 1260 Infinity II Multisampler can handle both vials and microtiter plates with ease and efficiency, and is designed for low carryover, as you can take clean to a whole new level with the multi-wash capability, cleaning all relevant injection parts between runs. This integrated feature flushes the injection needle outside with three solvents, and uses seat back flush procedures to reduce carryover to less than 9 ppm.

The 1260 Infinity II Diode-Array Detector WR features a 120 Hz data acquisition rate, perfectly suited for fast LC applications. This DAD WR detector is equipped with long-life deuterium lamps, which allow for the highest sensitivity and lowest detection limits over a wavelength range of 190-950 nm. The Agilent 1260 Infinity II LC System also allows for superior temperature control, with a range of 4°C (minimum of 20°C below ambient) to 110°C on certain columns, allowing for selectivity flexibility and reduces solvent viscosity to allow even faster separation. The 1260 Infinity II LC System is also equipped with the G1770A Universal Valve Drive, which enable users to adjust the system based on their application's needs with the simple change of an Agilent Quick Change Valve Head. Included is the
G4235A Bioinert 12 Position / 13 Port Solvent Selection Valve Head for the selection or fractionation of solvents.

The Agilent 1260 Infinity II LC System can be fully controlled from the Agilent MassHunter Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.


This Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.


INCLUDED:
The Agilent 1260 Infinity II LC System includes:
  • > G7112B Binary Pump
  • > G7115A DAD WR Detector
  • > G7167A Multisampler
  • > G7116B Multicolumn Thermostat
  • > G1170A Universal Valve Drive
  • > G4235A Bioinert 12 Position / 13 Port Solvent Selection Valve Head
  • > Datastation w/ MassHunter Workstation Software
  • > Can/Crossover Cables
  • > Agilent Lan Interface Card Built-In
  • > Solvent Tubing
  • > 4 x Bottles, Caps and Solvent Filters
  • > New Stainless Steel Capillaries
  • > 1/4" Wrench & Mobile Phase Priming Syringe
  • > Waste Tubing
  • > All Power Cords
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
  • > Full 180 Day Parts and Labor Warranty


Below is a List of Diagnostic Tests Performed On This System
G7115A Diode Array WR Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G7112B Binary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G7116B Multicolumn Thermostat Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G7167A Multisampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity II LC System.

Agilent 1260 Infinity II LC System Specifications

DAD WR Detector

Detection Type

1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 950 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 x 10^-5 AU at 254 and 750 nm
Drift < 0.9 x 10^-3 AU/h at 254 nm
Linear Absorbance Range > 2 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Slit Width 1, 2, 4, 8, 16 nm
Diode Width < 1 nm
Binary Pump
Settable Flow Range Set points 0.001 - 5 ml/min, in 0.001 ml/min increments
Recommended Flow Range

0.05 - 5.0 ml/min

Flow Precision ≤ 0.07% RSD or ≤ 0.02 min SD
Flow Accuracy ± 1% or 10 µl/min, whichever is greater
Pressure Operating Range Up to 60 MPa (600 bar, 8702 psi) up to 5 ml/min
Pressure Pulsation < 2% amplitude (typically < 1.3%) or < 0.3 MPa (3 bar, 44 psi), whichever is greater
Composition Range Settable range: 0 - 100%
Recommended range: 1 - 99% or 5 µl/min per channel
Composition Precision < 0.15 % RSD or < 0.04 min SD
Composition Accuracy ± 0.35% absolute, at 2 ml/min, at 10 MPa (100 bar)
Multisampler
Injection Range 0.1 - 90 µl in 0.1 µl increments
Injection Precision < 0.15% RSD or SD < 10nL, whatever is greater
Pressure Range Up to 800 bar
Sample Viscosity Range 0.2 - 5 cp
Sample Capacity 1H Drawer: up to 8 drawers and 16 positions
Shallow well plates (MTP)

2H Drawer: up to 4 drawers and 8 positions
MTP, deep well plates, vials, Eppendorf


3H Drawer: up to 2 drawers and 4 positions
MTP, deep well plates, vials up to 6 ml, Eppendorf
Injection Cycle Time < 10 seconds using following conditions:

Default draw speed: 100 ul/min
Default eject speed: 400 ul/min
Injection volume: 1 ul
Multiwash Outer needle wash and seat backflush for carryover reduction with up to 3 different solvents
Carry Over < 0.003% (30 ppm) Multisampler Standard Needle

<0.0009% (3 ppm) Multisampler Multiwash
Multicolumn Thermostat
Temperature Range 4°C to 110°C (minimum 20°C below ambient)
Temperature Stability ± 0.03°C
Temperature Accuracy ± 0.5°C (with calibration)
Temperature Precision 0.05°C
Heat-Up / Cool-Down Time 5 min from ambient to 40°C
10 min from 40°C to 20°C
< 30 min from 25°C to 100°C
Solvent Selection Valve
Maximum Pressure 210 bar
Fittings 10-32
Port-Port Volume 16.4 ul
Liquid Contact PEEK, Ceramic
pH Range 0-14