Agilent 1260 Infinity II HPLC G7115A DAD Detector
The Agilent 1260 Infinity II HPLC G7115A DAD Detector is engineered to provide top-notch optical performance, ensuring compliance with Good Laboratory Practices (GLP) and offering ease of maintenance. It features a rapid 120 Hz data acquisition rate that is ideal for ultra-fast liquid chromatography applications. Equipped with long-life deuterium and tungsten lamps, the detector achieves high intensity and low detection limits across a wide wavelength range of 190 to 950 nm. Unique RFID tags on all flow cells and UV lamps ensure accurate traceability of component data.
Users benefit from the detector’s ability to maintain sensitivity while simultaneously analyzing up to eight wavelengths. The programmable slit, adjustable from 1 to 16 nm, allows fine-tuning of sensitivity, linearity, and spectral resolution. Maintenance is streamlined through easily accessible front components for quick replacement. It also incorporates a built-in holmium oxide filter for rapid wavelength accuracy verification, and temperature controls for enhanced baseline stability. Additional features include diagnostic signals for monitoring temperature and lamp voltage, thus bolstering the detector's reliability in fast-paced analytical environments.
All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Agilent 1260 Infinity II HPLC G7115A DAD Detector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Flow Cell
- > Tungsten and Deuterium Lamps
- > Lab Advisor Calibration Report
- > Lan Cable / Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Agilent 1260 Infinity II HPLC G7115A DAD Detector Specifications
Detection Type
|
1024-element photodiode array
|
Light Source
|
Deuterium and tungsten lamps
|
Number of Signals
|
8
|
Data Rate
|
120 Hz
|
Wavelength Range
|
190 - 950 nm
|
Short Term Noise (ASTM) Single and Multi-Wavelength
|
< ± 0.7 x 10
-5 AU, at 254 and 750 nm
|
Drift
|
< 0.9 x 10
-3 AU/h at 254 nm
|
Linear Absorbance Range
|
> 2 AU (5%) at 265 nm
|
Wavelength Accuracy
|
± 1 nm
|
Wavelength Bunching
|
1 - 400 nm, programmable in 1 nm steps
|
Slit Width
|
1, 2, 4, 8, 16 nm
|
Diode Width
|
~ 1 nm
|
Flow Cell
|
Standard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum
|
Time Programmable
|
Wavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode
|
Dimensions (H x W x D)
|
5.5 x 15.6 x 17 in. (14 x 39.6 x 43.6 cm)
|
Weight
|
26.5 lb. (12 kg)
|
Electrical Requirements
|
100-240V, 50/60Hz, 110VA
|
|
|
|
|
|
|
|