Home > Chromatography - HPLC >

Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector
Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector
 
 



Our Price: $8,995.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 1 to 2 Business Days
Included Documentation: Delay Volume Detection and Lab Advisor Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1260ASFC
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector



Maximum System Flow
10 mL/min

Maximum Collection Volume
~20 mL with 30 x 48 mm tube or ~30 mL with 30 x 75 mm tube

Operating Modes
Discrete Fractions, Continuous Flow, Needle Into Location, Droplet Setup

Features
  • Integration of all standard collection modes and compatibility to multiple trigger sources provides compatibility with existing purification methods
  • Compact, closed design offers up to 216 fractions in vials or 384 fractions in SBS plates within small dimensions to save valuable bench space
  • Integrated delay volume sensor and automated calibration procedure ensure optimized sample recovery
  • Preconfigured tubing kits allow easy setup and provide optimized substance recovery with minimized peak dispersion at any flow rate
  • Module offers clustering functionality for easy enhancement of available fraction capacity to double or triple
  • Rapid vessel-to-vessel movement minimizes substance loss during movement between fraction vessels
The Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector is optimized for laboratories performing analytical-scale compound purification of nanogram to milligram quantities with typical flow rates between 0.1 and 10 mL/min. The module features the full set of collection modes and is compatible with a wide variety of trigger sources. SBS plates and four different tube sizes with various lengths are supported.

The Analytical-Scale Fraction Collector features a compact closed-box design, requires minimal bench space, and can be seamlessly integrated into any InfinityLab Analytical System. The built-in fraction delay sensor allows automated delay calibration for maximum substance recovery, and the four preconfigured capillary kits ensure minimum peak dispersion for maximum purity. Maximum capacity can be easily enhanced by clustering up to three modules.

All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector includes:
  • > Firmware Version 07.02 (Can be changed upon request)
  • > MTP Tray
  • > Front Cover
  • > Delay Volume Detection and Lab Advisor Report
  • > Operator's Guide
  • > Lan Cable / Power Cord
  • > Full 180 Day Parts and Labor Warranty

Agilent 1260 Infinity II HPLC G1364F Analytical-Scale Fraction Collector Specifications

Delay Volume (in ul)

Fraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~10

Needle: ~4

Maximum System Flow 10 mL/min
Maximum Collection Volume

~20 mL with 30 x 48 mm (OD x L) tube

~30 mL with 30 x 75 mm (OD x L) tube

Maximum Capacity 3 fraction collectors in parallel plus one recovery fraction collector
Cooling Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
Trigger Modes

Time slices

Peak (threshold, up- / downslope)

Timetable (combination of time intervals and peak)

Manual trigger (supported only with Agilent Instant Pilot G4208A)

Trigger Sources G7115A, G7165A, G7114A, G6120BA, G6130BA, G7121A, G4260B, G7162A
Operating Modes

Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position

Continuous flow: optional, available only when using deep well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste

Needle into location: Needle pushes into the vessel as deep as specified, for the use with capped vials and test tubes and well plates with closing mats

Droplet setup mode: enables the fraction collector to collect small fractions without bubbles. The tip of the fraction collector needle initially moves down to the bottom of the well. Then it slowly moves upwards while the fraction is collected.

Maximum Time to Move Between Neighboring Vessels

Movement in x-direction: < 0.15 s

Movement in y-direction: < 0.3 s

Diverter Valve 3/2 valve, with switching time < 100 ms
Maximum Pressure 6 bar at the diverter valve during switching
Plates/Trays 4 x well-plates full tray (MTP), only one type of well-plates can be used at a time in one tray
Fraction Containers

30 x 48 mm (OD x L) tubes, ~20 mL / tube

25 x 48 mm (OD x L) tubes, ~15 mL / tube

16 x 48 mm (OD x L) tubes, ~11 mL / tube

12 x 48 mm (OD x L) tubes, ~8 mL / tube

Maximum Tube Height

48 mm with long needle assembly G1367-87200

75 mm with short needle assembly G1364-87202

Dimensions (H x W x D) 8 x 13.5 x 17 in. (20 x 34.5 x 44 cm)
Weight 29.8 lb. (13.5 kg)
Electrical Requirements 100-240V, 50/60Hz
Downloads


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Chromatography - HPLC
Brand
Brand > Agilent
Chromatography Component
Chromatography Component > Fraction Collectors