Agilent 1260 Infinity I HPLC G1321B FLD Detector
The Agilent 1260 Infinity I HPLC G1321B FLD Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The G1321B is also designed for the highest optical performance, GLP compliance, and easy maintenance. Some of the features of the G1321B FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Agilent 1260 Infinity I HPLC G1321B FLD Detector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Calibration Report
- > 8μl Flow Cell
- > Lab Advisor Calibration Report
- > Lan Cable / Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Agilent 1260 Infinity I HPLC G1321B FLD Detector Specifications
Detection Type
|
Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis
|
Performance Specifications
|
Single wavelength operation: • RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.
|
Light source
|
Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h
|
Pulse frequency
|
296 Hz for single signal mode 74 Hz for economy mode
|
Excitation Monochromator
|
Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm
|
Emission Monochromator
|
Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm
|
Reference System:
|
in-line excitation measurement
|
Timetable programing
|
up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters
|
Spectrum acquisition:
|
Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All
|
Wavelength characteristic
|
Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting
|
Flow cells
|
Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz
|
Dimensions (H x W x D)
|
7 x 13.5 x 17 in. (14 x 34.5 x 43.5 cm)
|
Weight
|
26 lb. (11.5 kg.)
|
|
|
|
|
|
|
|