Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector
The Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector is designed for semipreparative-scale purification tasks, efficiently handling milligram to low gram quantities. This advanced collector supports a maximum flow rate of 100 mL/min and offers two collection modes, including discrete fractions and continuous flow. It integrates smoothly with numerous trigger sources. Equipped with a 3/2 diverter valve featuring a low internal volume of 15 ul and a quick switching time under 100 ms, it ensures minimal delay and high precision.
The maximum capacity can easily be enhanced by clustering up to three modules simultaneously through a 12-position, 13-port selector valve. Additionally, it offers cooling options when paired with the G1330B for enhanced performance, depending on the collected fraction's volume and ambient conditions. The collector includes a tray that holds 215 test tubes, with an OD of 12 mm and maximum height of 48 mm. Its delay calibration is managed by a single wavelength absorbance detector operating at 654 nm, ensuring accurate and reliable operation. This model supports multiple trigger modes such as time slices, peak detection, timetable, and manual triggers, making it a flexible choice for a variety of laboratory settings.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > 215 Test Tube Tray (12 mm OD, Max. Height 48 mm)
- > Front Cover
- > Delay Volume Detection and Lab Advisor Report
- > Lan Cable / Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector Specifications
Delay Volume (in ul)
|
Fraction collector inlet to diverter valve: ~500 (typical, depends on length of the tubing)
Diverter valve: ~15
Diverter valve to needle: ~110
Needle: ~5
|
Maximum System Flow
|
100 mL/min
|
Maximum Capacity
|
3 fraction collectors in parallel plus one recovery fraction collector connected via 12-position, 13-port selector valve (PN G1160A)
|
Cooling
|
Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
|
Trigger Modes
|
Time slices
Peak (threshold, up- / downslope)
Timetable (combination of time intervals and peak)
Manual trigger (supported only with Agilent Instant Pilot G4208A)
|
Trigger Sources
|
G1315C/D, G4212B, G1365C/D, G1321A, G1946C/D, G1956A/B
|
Operating Modes
|
Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position
Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
|
Diverter Valve
|
3/2 valve with low internal volume (15 ul), switching time < 100 ms, maximum operating presure 6 bar
|
Included Tray
|
Full tray with 215 test tubes (12 mm OD, max. height 100 mm, ~7 ml / tube)
|
Delay Calibration Sensor
|
Single wavelength absorbance detector working at 654 nm, consisting of a LED and photo diode
|
Dimensions (H x W x D)
|
8 x 13.5 x 17 in. (20 x 34.5 x 44 cm)
|
Weight
|
29.8 lb. (13.5 kg)
|
Electrical Requirements
|
100-240V, 50/60Hz
|
|
|
|
|
|
|
|