Agilent 1200 HPLC System w/ VWD & FLD
Agilent 1200 HPLC System w/ VWD & FLD
 
 



Our Price: $29,995.00
Sale Price: $27,715.00
Money Saved: $2,280.00

Price with Selected Options: $27,715.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1200FLDVW

Please Select an Option Below

Select Included Option*:

Please Select an Option Below

Select Additional Detector*:


Qty:
Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1200 HPLC System w/ VWD & FLD



Wavelength Range (VWD)
190 to 600 nm

Excitation Wavelength Range (FLD)
200 to 700 nm

Emission Wavelength Range (FLD)
280 to 900 nm

Features
  • Quaternary pump with variable stroke volumes for stable, pulse-free flow (Binary Pump available if preferred, please inquire)
  • Electronically activated inlet valve prevents vapor formation, ideal for volatile solvents
  • High-speed proportioning valve and pre-configured degasser for flexible low-pressure mixing
  • Vacuum degasser reduces helium dependency and operational costs
  • Variable Wavelength Detector with deuterium lamp covering 190–600 nm for high sensitivity
  • FLD detector with multi-signal fluorescence and rapid online scanning for detailed spectral data
  • Xenon flash lamp in FLD with economy mode for energy-efficient operation
  • Adjustable slit width from 1 to 16 nm for optimized sensitivity and noise control
  • Versatile flow cell options for high-pressure, micro, and semi-micro applications
  • Extensive diagnostic and GLP features with Clarity software compatibility for real-time troubleshooting

The Agilent 1200 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1200 both remarkably easy-to-use and maintenance-free. It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance.


The Agilent 1200 Variable Wavelength Detector lowers detection limits with simplified optics for high sensitivity, low baseline drift, and wide linear range. This wide linear range allows for reliable simultaneous quantitation of main and side products and impurities. The Agilent 1200’s temperature management system ensures optimum baseline stability-even under rough ambient conditions. This detector features superb illumination using combined deuterium and tungsten lamps for the highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution. The programmable slit helps you explore the spectral landscape for faster sample characterization, ensuring higher sensitivity or lower baseline noise as necessary on the 1200. Slit settings can be stored and reported from 1 – 16 nm with raw data for GLP traceability.


The unit can be operated with a hand-held controller or computer running Clarity software. The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.


This Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.


Recertified Agilent 1200 System

INCLUDED:
The Agilent 1200 HPLC System w/ VWD & FLD includes:
  • > G1311A Quaternary Pump or G1312A Binary Pump
  • > G1329A Thermal Autosampler
  • > G1330B Thermal Unit
  • > G1314A VWD Detector
  • > G1321A FLD Detector
  • > G1316A TCC
  • > G1322A Degasser
  • > Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
  • > Chemstation version 4.3 Software installed
  • > Can/Crossover Cables
  • > Agilent G1369 Lan Interface Card
  • > Solvent Tubing
  • > 4 x Bottles, Caps and Solvent Filters
  • > New Stainless Steel Capillaries
  • > 1/4" Wrench & Mobile Phase Priming Syringe
  • > Waste Tubing
  • > All Power Cords
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
  • > Full 180 Day Parts and Labor Warranty


Below is a List of Diagnostic Tests Performed On This System
G1314A Variable Wavelength Detector & G1321A Fluorescence Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1311A Quaternary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316A Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329A Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 HPLC System.

Agilent 1200 HPLC System with VWD & FLD Detector Specifications

Detection type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short term noise (ASTM) Single
and Multi-Wavelength

± 0.75 × 10-5AU at 254 nm

Drift

3 × 10-4AU/hr at 254 nm

Linear Absorbance range > 2 AU (5%) upper limit
Wavelength accuracy ± 1 nm
Slit width 1, 2, 4 , 8, 16 nm
Band Width 6.5 nm typical
Diode Width < 1 nm
Flow Cells

Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum


Agilent 1200 FLD Detector Specifications


Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W

Pulse frequency

296 Hz for single signal mode 74 Hz for spectral mode

Excitation Monochromator

Range: 200 nm - 700 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: 280 nm - 900 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 400 nm

Reference System:

In-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition:

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200-400 nm, 10 nm step) Step size: 1-20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Control and data evaluation

Agilent ChemStation for LC, Agilent Instant Pilot G4208A or Agilent Control Module G1323B with limited spectral data analysis and printing of spectra

Communications

Controller-area network (CAN), GPIB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W

Pulse frequency

296 Hz for single signal mode 74 Hz for spectral mode



Computer Specifications

Processor Intel Core I5-8500 CPU
RAM 32.0 GB
Hard Drive 500GB Internal SSD
Operating System Windows 11 Professional, 64-bit