Agilent 1200 HPLC System w/ VWD & FLD
Wavelength Range (VWD) 190 to 600 nm
Excitation Wavelength Range (FLD) 200 to 700 nm
Emission Wavelength Range (FLD) 280 to 900 nm
- Quaternary pump with variable stroke volumes for stable, pulse-free flow (Binary Pump available if preferred, please inquire)
- Electronically activated inlet valve prevents vapor formation, ideal for volatile solvents
- High-speed proportioning valve and pre-configured degasser for flexible low-pressure mixing
- Vacuum degasser reduces helium dependency and operational costs
- Variable Wavelength Detector with deuterium lamp covering 190–600 nm for high sensitivity
- FLD detector with multi-signal fluorescence and rapid online scanning for detailed spectral data
- Xenon flash lamp in FLD with economy mode for energy-efficient operation
- Adjustable slit width from 1 to 16 nm for optimized sensitivity and noise control
- Versatile flow cell options for high-pressure, micro, and semi-micro applications
- Extensive diagnostic and GLP features with Clarity software compatibility for real-time troubleshooting
The Agilent 1200 HPLC System guarantees the most efficient
mixing and pulse-free solvent delivery for consistently fast and accurate
results. The system’s optimized design using a quaternary pump allows variable
stroke volumes for stable solvent flow. This electronically activated inlet
valve runs synchronous to the pistons to eliminate vapor formation in volatile
solvent, making the Agilent 1200 both remarkably easy-to-use and
maintenance-free. It also features a high-speed proportioning valve and a
pre-configured degasser, which allow convenient low-pressure mixing and a large
solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced
operating costs without the use of helium and optimum instrument performance.
The Agilent 1200 Variable Wavelength Detector lowers detection limits with simplified optics for high sensitivity, low baseline drift, and wide linear range. This wide linear range allows for reliable simultaneous quantitation of main and side products and impurities. The Agilent 1200’s
temperature management system ensures optimum baseline stability-even under
rough ambient conditions. This detector features superb illumination using
combined deuterium and tungsten lamps for the highest intensity and lowest
detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest
spectral resolution. The programmable slit helps you explore the spectral
landscape for faster sample characterization, ensuring higher sensitivity or
lower baseline noise as necessary on the 1200. Slit settings can be stored and
reported from 1 – 16 nm with raw data for GLP traceability.
The unit can be operated with a hand-held controller or
computer running Clarity software. The HPLC System features extensive
diagnostics with compatible data analysis software for on-site and remote
trouble-shooting.
This Agilent system is in excellent condition and will be fully tested to perform at factory
specifications before being shipped.
Recertified Agilent 1200 System
The Agilent 1200 HPLC System w/ VWD & FLD includes:
- > G1311A Quaternary Pump or G1312A Binary Pump
- > G1329A Thermal Autosampler
- > G1330B Thermal Unit
- > G1314A VWD Detector
- > G1321A FLD Detector
- > G1316A TCC
- > G1322A Degasser
- > Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
- > Chemstation version 4.3 Software installed
- > Can/Crossover Cables
- > Agilent G1369 Lan Interface Card
- > Solvent Tubing
- > 4 x Bottles, Caps and Solvent Filters
- > New Stainless Steel Capillaries
- > 1/4" Wrench & Mobile Phase Priming Syringe
- > Waste Tubing
- > All Power Cords
- > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
- > Full 180 Day Parts and Labor Warranty
Below is a List of Diagnostic Tests Performed On This System
- Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
- Dark Current Test: The test measures the dark current from the detector optic.
- Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
- Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
- Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
- Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
- Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
- Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
- Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
- Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
- 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 HPLC System.
Agilent 1200 HPLC System with VWD & FLD Detector Specifications
Detection type
|
Double-beam photometer
|
Light Source
|
Deuterium lamp
|
Wavelength Range
|
190 - 600 nm
|
Short term noise (ASTM) Single
and Multi-Wavelength
|
± 0.75 × 10-5AU at 254 nm
|
Drift
|
3 × 10-4AU/hr at 254 nm
|
Linear Absorbance range
|
> 2 AU (5%) upper limit
|
Wavelength accuracy
|
± 1 nm
|
Slit width
|
1, 2, 4 , 8, 16 nm
|
Band Width
|
6.5 nm typical
|
Diode Width
|
< 1 nm
|
Flow Cells
|
Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
|
Agilent 1200 FLD Detector Specifications
Detection Type
|
Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis
|
Performance Specifications
|
10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)
|
Light source
|
Xenon Flash Lamp, normal mode 20 W, economy mode 5 W
|
Pulse frequency
|
296 Hz for single signal mode 74 Hz for spectral mode
|
Excitation Monochromator
|
Range: 200 nm - 700 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 300 nm
|
Emission Monochromator
|
Range: 280 nm - 900 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 400 nm
|
Reference System:
|
In-line excitation measurement
|
Timetable programing
|
up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters
|
Spectrum acquisition:
|
Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200-400 nm, 10 nm step) Step size: 1-20 nm Spectra storage: All
|
Wavelength characteristic
|
Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting
|
Flow cells
|
Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz
|
Control and data evaluation
|
Agilent ChemStation for LC, Agilent Instant Pilot G4208A or Agilent Control Module G1323B with limited spectral data analysis and printing of spectra
|
Communications
|
Controller-area network (CAN), GPIB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
|
Detection Type
|
Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis
|
Performance Specifications
|
10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)
|
Light source
|
Xenon Flash Lamp, normal mode 20 W, economy mode 5 W
|
Pulse frequency
|
296 Hz for single signal mode 74 Hz for spectral mode
|
Computer Specifications
|
Processor
|
Intel Core I5-8500 CPU
|
RAM
|
32.0 GB
|
Hard Drive
|
500GB Internal SSD
|
Operating System
|
Windows 11 Professional, 64-bit
|
- Verify uniformity of main and residential firmware across all components, updating as necessary to ensure compatibility
- Confirm successful communication between software and the HPLC system, validating data transfer integrity
- Check the degasser’s internal vacuum to confirm it reaches the specified vacuum level for optimal performance
- Replace inlet, outlet, purge valve, and pump seals in the system pump to maintain reliable operation
- Ensure system pump passes pressure and leak tests, confirming secure and efficient performance
- Replace all capillary tubing with new OEM stainless steel tubing for durability and precision
- Remove autosampler transport assembly, replace X and Y bearings, and thoroughly clean carrier rails to remove debris and contaminants
- Replace metering valve seal, autosampler needle, and needle seat for consistent sampling accuracy
- Test column compartment switching valve functionality and replace its seal if necessary
- Confirm column compartment passes thermostat test to maintain precise temperature control
- Remove and clean internal detector optics for clear and accurate signal detection
- Replace UV and Vis detector lamps to ensure optimal light source stability and performance
- Verify flow cell absorbance meets manufacturer’s specifications for accurate measurement
- Confirm system response to isocratic test sample, ensuring stable and reproducible results
Technician Inspection and Recertification Checklist: HPLC Systems
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify firmware uniformity and update as necessary
|
Completed
|
|
Confirm software communication with HPLC system
|
Completed
|
|
Check degasser vacuum level for optimal performance
|
Completed
|
|
Replace inlet, outlet, purge valve, and pump seals
|
Completed
|
|
Ensure pump passes pressure and leak tests
|
Completed
|
|
Replace all capillary tubing with OEM stainless steel tubing
|
Completed
|
|
Remove autosampler transport assembly, replace bearings, and clean rails
|
Completed
|
|
Replace metering valve seal, autosampler needle, and needle seat
|
Completed
|
|
Test column compartment switching valve and replace seal if needed
|
Completed
|
|
Confirm thermostat test in column compartment
|
Completed
|
|
Clean internal detector optics
|
Completed
|
|
Replace UV and Vis detector lamps
|
Completed
|
|
Verify flow cell absorbance meets manufacturer’s specifications
|
Completed
|
|
Confirm system response to isocratic test sample
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|