Home > Chromatography - HPLC >

Agilent 1200 HPLC System w/ DAD & FLD
Agilent 1200 HPLC System w/ DAD & FLD
 
 



Our Price: $31,395.00
Sale Price: $28,935.00
Money Saved: $2,460.00

Price with Selected Options: $28,935.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1200FLD

Please Select an Option Below

Select Included Option*:

Please Select an Option Below

Select Additional Detector*:


Qty:
Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1200 HPLC System with Diode Array Detector and Fluorescence Detector



Wavelength Range (DAD)
190 to 640 nm

Wavelength Range (FLD)
Ex: 200 to 700 nm / Em: 280 to 900 nm

Flow Rate Range
0.001 to 10 ml/min

Features
  • Ensures efficient mixing and pulse-free solvent delivery for fast and accurate results
  • Equipped with a quaternary pump allowing variable stroke volumes for stable solvent flow (binary pump available, please inquire)
  • Electronically activated inlet valve eliminates vapor formation in volatile solvents
  • Features a high-speed proportioning valve and pre-configured degasser for flexible solvent options
  • Vacuum degasser reduces operating costs by eliminating the need for helium
  • Diode array design enables simultaneous detection of up to eight compound-specific wavelengths
  • FLD enhances detection with high-intensity flash lamp and multi-wavelength spectral scanning capabilities
  • Programmable slit width from 1 to 16 nm optimizes sensitivity, linearity, and spectral resolution
  • Standard flow cell with 13 µl volume and 10 mm path length for precise measurements
  • Compatible with Agilent ChemStation for seamless control and data evaluation
  • Advanced diagnostics and GLP features, including early maintenance feedback and error tracking
  • Integrated holmium oxide filter ensures accurate wavelength verification for reliable performance

The Agilent 1200 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1200 both remarkably easy-to-use and maintenance-free. It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance.


The Agilent 1200 Diode Array Detector verifies separation quality with peak purity, multiple signals, and spectral libraries during your analytical quantification, offering an extended wavelength range with the highest sensitivity. The VWD and diode array detectors allow for automated wavelength verification for performance tracking. The Agilent 1200’s temperature management system ensures optimum baseline stability-even under rough ambient conditions. This detector features superb illumination using combined deuterium and tungsten lamps for the highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution. The programmable slit helps you explore the spectral landscape for faster sample characterization, ensuring higher sensitivity or lower baseline noise as necessary on the 1200. Slit settings can be stored and reported from 1 – 16 nm with raw data for GLP traceability.


The unit can be operated with a hand-held controller or computer running Clarity software. The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.

This Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.


Recertified Agilent 1200 System

INCLUDED:
The Agilent 1200 HPLC System w/ DAD & FLD includes:
  • > G1311A Quaternary Pump or G1312A Binary Pump
  • > G1329A Thermal Autosampler
  • > G1330B Thermal Unit
  • > G1315C DAD Detector
  • > G1321A FLD Detector
  • > G1316A TCC
  • > G1322A Degasser
  • > Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
  • > Chemstation version 4.3 Software installed
  • > Can/Crossover Cables
  • > Agilent G1369 Lan Interface Card
  • > Solvent Tubing
  • > 4 x Bottles, Caps and Solvent Filters
  • > New Stainless Steel Capillaries
  • > 1/4" Wrench & Mobile Phase Priming Syringe
  • > Waste Tubing
  • > All Power Cords
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
  • > Full 180 Day Parts and Labor Warranty


Below is a List of Diagnostic Tests Performed On This System
G1315C Diode Array Detector & G1321A Fluorescence Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1311A Quaternary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316A Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329A Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1200 HPLC System.

Agilent 1200 HPLC System with DAD Detector Specifications

Type Specification
Detection type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 950 nm
Short term noise (ASTM) Single
and Multi-Wavelength
± 1 × 10-5AU at 254 and 750 nm
Drift 2 × 10-3AU/hr at 254 nm
Linear Absorbance range
> 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Slit width 1, 2, 4 , 8, 16 nm

Diode Width
< 1 nm
Flow Cell

Standard: 13 µl volume, 10 mm cell

path length and 120 bar (1760 psi)

pressure maximum

Control and Data Evaluation Agilent ChemStation for LC
Analog Outputs Recorder/integrator: 100 mV or 1 V,

output range 0.001 – 2 AU, two

outputs

Communications

Controller-area network (CAN), GPIB,

RS-232C, APG Remote: ready, start,

stop and shut-down signals, LAN

optional
Safety and Maintenance Extensive diagnostics, error detection

and display (through control module

and ChemStation), leak detection, safe

leak handling, leak output signal for

shutdown of pumping system. Low

voltages in major maintenance areas.

GLP Features Early maintenance feedback (EMF) for

continuous tracking of instrument

usage in terms of lamp burn time with

user-settable limits and feedback

messages. Electronic records of

maintenance and errors. Verification of

wavelength accuracy with built-in

holmium oxide filter.

Housing All Materials recyclable


Agilent 1200 FLD Detector Specifications

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W

Pulse frequency

296 Hz for single signal mode 74 Hz for spectral mode

Excitation Monochromator

Range: 200 nm - 700 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: 280 nm - 900 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator:concave holographic grating, F/1.6, blaze: 400 nm

Reference System:

in-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition:

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200-400 nm, 10 nm step) Step size: 1-20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Control and data evaluation

Agilent ChemStation for LC, Agilent Instant Pilot G4208A or Agilent Control Module G1323B with limited spectral data analysis and printing of spectra

Communications

Controller-area network (CAN), GPIB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

10 fg Anthracene, Ex=250 nm, Em=400 nm* RAMAN single wavelength (H2O) > 500 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime) RAMAN dual wavelength (H2O) > 300 with Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds responsetime)

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W

Pulse frequency

296 Hz for single signal mode 74 Hz for spectral mode



Computer Specifications

Processor Intel Core I5-8500 CPU
RAM 32.0 GB
Hard Drive 500GB Internal SSD
Operating System Windows 11 Professional, 64-bit
Downloads


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Chromatography - HPLC
Brand > Agilent
Chromatography Component
Chromatography Component > Systems
Brand