Agilent 1200 HPLC G1364C Fraction Collector
Maximum Tube Volume
ca. 45 ml
Test Tube/Plate Sizes
Minimum 48 mm to 75 mm maximum
- Customizable trigger modes, including time slices, peak detection, and manual trigger
- Flexible operating modes with discrete fraction and continuous flow options
- Equipped with a single wavelength absorbance detector for accurate delay calibration
- Low-volume 3/2 diverter valve with fast switching time and a maximum pressure of 6 bar
- Supports up to three parallel fraction collectors and one recovery collector for high-throughput workflows
- Interfaces include CAN, LAN, RS232C, and remote signals for integration with external devices
- Enhanced safety features such as leak detection, error handling, and an exhaust fan for hazardous vapors
The Agilent 1200 HPLC G1364C Fraction Collector is designed for optimized fraction collection capability without compromises. Users can choose between three dedicated fraction collectors depending on sample amount, flow rate, and the types of collection containers. All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1200 HPLC G1364C Fraction Collector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Tray
- > Delay Volume Detection and Lab Advisor Diagnostic Report
- > Lan Cable / Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Agilent 1200 HPLC G1364C Fraction Collector Specifications
Trigger Modes
|
Time slices, Peak (threshold, up- /downslope), Timetable (combination
of time intervals and peak) and Manual trigger (supported only with
G1323BControl Module)
|
Operating Modes
|
Discrete fractions: default mode for all vessels. The flow is
diverted to waste, while moving from one vessel position to the next vessel
position Continuous flow: optional, available only when using well plates. It
is possible to move from one well plate position to the next one without
diverting the flow into the well plate to waste
|
Test Tube/Plate Sizes
|
Minimum 48 mm to 75 mm maximum
|
Maximum Tube Volume
|
ca. 45 ml
|
Maximum Flow Rate
|
100 ml / min (depending on viscosity and generated back pressure,
max. 6 bar at the diverter valve)
|
Delay Volumes [μl]
|
Fraction collector inlet to diverter valve: -500 (typical, depends on
length of the tubing)
Diverter valve: ~15
Diverter valve to needle: ~110
Needle: ~5
|
Delay Calibration Sensor
|
Single wavelength absorbance detector working at 654 nm, consisting
of a LED and a photo diode
|
Diverter Valve
|
3/2 Diverter valve with low internal volume (15 μl), switching time
< 100 ms, maximum operating pressure 6 bar
|
Maximum Capacity
|
3 fraction collectors in parallel plus one recovery fraction
collector connected via 12-Position, 13-Port Selector valve
|
Interfaces
|
Controller-area network (CAN). optional; LAN or external contacts
interface RS232C, APG-remote (for remote start / stop signals to / from other
modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent
approved external devices like valves
|
Safety Features
|
Leak detection and safe leak handling, error detection and display,
exhaust fan for fume extraction of hazardous vapors
|
Agilent 1200 G1364C Manual
Click Here to View all the Technical Specs for the G1364C Fraction Collector
|
|
|
|
|
|
|