Agilent 1200 HPLC G1362A RID Detector
Agilent 1200 HPLC G1362A RID Detector
 
 



Stock Notification!

The Agilent 1200 HPLC G1362A RID Detector you were interested in is currently unavailable, but we have found a great alternative at an excellent price!

Our Price: $8,495.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation: Lab Advisor Calibration Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1200RID
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1200 HPLC G1362A RID Detector


The Agilent 1200 HPLC G1362A RID Detector is a HPLC refractive index detector (RID) detector that provides excellent performance for entry-level UHPLC and HPLC differential refractometer (DRI) experiments. This detector is a differential refractometer that measures the deflection of a light beam due to the difference in refractive index between the liquids in the sample and reference cells of a single flow cell. A beam of light from the lamp passes through a flow cell which is separated diagonally into sample and reference cells. At the rear of the flow cell a mirror reflects the light back through the flow cell and via a zero glass, which affects the path of the light beam, to the light receiver. The light receiver has two diodes each of which produces an electrical current proportional to the amount of light that falls upon it. Rapid equilibration times and stable baselines make it easy to analyze carbohydrates, triglycerides, organic acids, and pharmaceutical excipients. The Agilent 1200 HPLC G1362A RID Detector is the detector of choice for polymer characterization using gel permeation chromatography (GPC) and size exclusion chromatography (SEC).

The Agilent 1200 HPLC G1362A RID Detector also features optimized light levels, automatically adjusting the light intensity to compensate for lamp degradation and flow cell staining. Users can conduct automatic purging of the reference flow cell as well using programmable purge and wait times. This G1362A RID Detector features minimum baseline noise for excellent sensitivity and low limits of detection. Users may also utilize the recycle valve to keep the system at operating conditions, avoiding warm-up wait times and saving solvents.

All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 1200 HPLC G1362A RID Detector includes:
  • > Firmware Version 07.02 (Can be changed upon request)
  • > Front Cover
  • > Lab Advisor Calibration Report
  • > Power Cord
  • > Operator's Manual
  • > Full 180 Day Parts and Labor Warranty

Agilent 1200 HPLC G1362A RID Detector Specifications

Detection Type Refractive Index

Refractive Index Range

1.00 to 1.75 RIU, calibrated

Measurement Range

± 600 x 10 -6 RIU

Optical Zeroing

via set screw

Optics Temperature Control

5°C above ambient to 55°C

Sample Cell

Volume 8 µL, maximum pressure 5 bar (0.5 Mpa), maximum flow rate 5 mL/min

Valves

Automatic purge and automatic solvent recycle

Volumes

Inlet port to sample cell: 62 µL

Inlet port to outlet port: 590 µL

Liquid Contact Materials

316 stainless steel, teflon and quartz glass

pH Range

2.3 to 9.5

Short Term Noise

< ± 2.5 x 10 -9 RIU

Drift

< 200 x 10 -9 RIU/hour

Time Programmable Parameters

Polarity and peak width

Detector Zero

Automatic zero before analysis

Dimensions (H x W x D)

7 x 13.5 x 17 in. (18 x 34.5 x 43.5 cm)

Weight

38 lb. (17 kg.)

Electrical Requirements

100-240V, 50/60Hz