Agilent 1100 HPLC System w/VWD & FLD Detectors
Agilent 1100 HPLC System w/VWD & FLD Detectors
 
 



Our Price: $23,225.00
Sale Price: $16,995.00
Money Saved: $6,230.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 3 to 5 Business Days
Included Documentation Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report

Request a Formal Quote


Quantity in Stock:1

Product Code: AG-1100SS
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Agilent 1100 HPLC System with Variable Wavelength Detector & Fluorescence Detector


The Agilent 1100 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1100 both remarkably easy-to-use and maintenance-free. It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance.

The Agilent 1100 Variable Wavelength Detector lowers detection limits with simplified optics for high sensitivity, low baseline drift, and wide linear range. This wide linear range allows for reliable simultaneous quantitation of main and side products and impurities. The Agilent 1100 VWD’s minimum baseline noise gives it the highest baseline stability for the lowest detection limits. This VWD offers programmable wavelength switching for sensitivity and optimized selectivity optimized to each analyte’s elution, along with stop-flow wavelength scanning for quick wavelength optimization.

The Agilent 1100 Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.

The unit can be operated with a hand-held controller or computer running Clarity software. The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.

All of our equipment is fully tested to perform at factory specifications before being shipped.


INCLUDED:
The Agilent 1100 HPLC System w/VWD & FLD Detectors includes:
  • > G1311A Quat Pump (Binary Pump Available)
  • > G1329A Thermal Autosampler
  • > G1330B ALS Therm
  • > G1314A VWD Detector
  • > G1321A FLD Detector
  • > G1316A Column Compartment
  • > G1379A Degasser
  • > Windows 10 Professional 64-Bit Data Station with Flatscreen Monitor
  • > Chemstation version 4.3 software installed
  • > Flatscreen Monitor
  • > Can/Crossover Cables
  • > Agilent G1369 Lan Interface Card
  • > Solvent Tubing
  • > 4 x Bottles, Caps and Solvent Filters
  • > Stainless Steel Capillaries
  • > 1/4" Wrench & Mobile Phase Priming Syringe
  • > Waste Tubing
  • > All Power Cords
  • > Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
  • > Full 180 Day Parts and Labor Warranty


Below is a List of Diagnostic Tests Performed On This System
G1314A Variable Wavelength Detector & G1321A Fluorescence Detector Diagnostic Tests:
  • Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.
  • Dark Current Test: The test measures the dark current from the detector optic.
  • Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.
  • Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.
  • Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.
  • Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.
G1311A Quaternary Pump Diagnostic Tests:
  • Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.
  • Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.
G1316A Column Compartment Diagnostic Tests:
  • Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.
G1329A Autosampler Diagnostic Tests:
  • Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.
System Tests:
  • 4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1100 HPLC System.

Agilent 1100 HPLC System Specifications


Type Specification
Detection type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short term noise (ASTM) Single
and Multi-Wavelength

± 0.75 × 10-5AU at 254 nm

Drift

3 × 10-4AU/hr at 254 nm

Linear Absorbance range
> 2 AU (5%) upper limit
Wavelength accuracy ± 1 nm
Slit width 1, 2, 4 , 8, 16 nm
Band Width 6.5 nm typical
Diode Width < 1 nm
Flow Cell

Standard: 14-µl volume, 10-mm

cell path length and 40 bar

(588 psi) pressure maximum

High pressure: 14-µl volume,

10-mm cell path length and

400 bar (5880 psi) pressure

maximum

Control and Data Evaluation Agilent ChemStation for LC
Analog Outputs Recorder/integrator: 100 mV or 1 V,

output range 0.001 – 2 AU, two

outputs

Communications

Controller-area network (CAN), GPIB,

RS-232C, APG Remote: ready, start,

stop and shut-down signals, LAN

optional
Safety and Maintenance Extensive diagnostics, error detection

and display (through control module

and ChemStation), leak detection, safe

leak handling, leak output signal for

shutdown of pumping system. Low

voltages in major maintenance areas.

GLP Features Early maintenance feedback (EMF) for

continuous tracking of instrument

usage in terms of lamp burn time with

user-settable limits and feedback

messages. Electronic records of

maintenance and errors. Verification of

wavelength accuracy with built-in

holmium oxide filter.

Housing All Materials recyclable



Computer Specifications

Model

Dell Optiplex 7050 Desktop PC

Processor

Intel Core i5-6500 Processor 3.6GHz

Ram

16GB

Hard Drive

250GB Internal SSD

Operating System

Windows 10 Professional, 64bit



Agilent 1100 Series HPLC System Operator's Manual

Click Here to View all the Technical Specs for the Agilent 1100 System