Agilent 1100 HPLC G1389A MicroALS Autosampler


The Agilent 1100 Series Thermostatted Micro Autosampler has a settable injection volume allowing for 0.01 to 8 µl with a small loop capillary and 0.01 to 40 µl with an extended loop capillary. There is a precision of < 0.5 % RSD from 5 to 40 µl, < 1 % RSD from 1 to 5 µl, and < 3 % RSD from 0.2 to 1 µl. The G1389A features a Thermostattable Tray for 100 x 2 ml vials and can be used with microvials (100 or 300 µl) with sleeves. It has early maintenance feedback (EMF) and electronic records of maintenance and errors. Safety features include a leak detection and safe leak handling, low voltages in maintenance areas, and error detection and display.

All of our equipment is fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Agilent 1100 HPLC G1389A MicroALS Autosampler includes:
  • > Firmware Version 07.02 (Can be changed upon request)
  • > Tray
  • > Front Cover
  • > Lab Advisor Documentation
  • > Lan Cable / Power Cord
  • > Operator's Manual
  • > Full 180 Day Parts and Labor Warranty

Agilent 1100 HPLC G1389A MicroALS Autosampler Specifications

Weight

14.2 kg (31.3 lbs)

Dimensions (H x W x D)

200 x 345 x 435 mm (8 x 13.5 x 17 in)

Line Voltage

Line frequency

100 – 120 or 220 – 240 VAC, ± 10 %

50 or 60 Hz, ± 5 %

Power consumption (apparent power)

Power consumption (active power)

300 VA max.

200 W max.

Ambient operating temperature

Ambient non-operating temperature

4 – 55 °C (41 – 131 °F)

40 to 70 °C (-4 to 158 °F)

Humidity

< 95 %, at 25 – 40 °C (77 – 104 °F) non-condensing

Tray

Thermostattable Tray for 100 x 2 ml vials Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)

Settable injection volume

0.01 to 8 µl with small loop capillary

0.01 to 40 µl with extended loop capillary

Precision

Typically < 0.5 % RSD from 5 to 40 µl Typically < 1 % RSD from 1 to 5 µl Typically < 3 % RSD from 0.2 to 1 µl

Minimum sample volume

1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials

Carryover

Typically < 0.1 % without automated needle wash Typically < 0.05 % with external needle cleaning and 1 µl injection volume

Sample viscosity range

0.2 - 5 cp

Recommended pH-range

1.0 - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries

Material in contact with solvent

Stainless steel, sapphire, PTFE, PEEK, fused silica, Vespel

GLP features

Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications

Controller-area network (CAN), GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output

Housing

All materials are recyclable


Agilent 1100 G1389A Manual

Click Here to View the Technical Specs for the G1389A Autosampler


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Chromatography - HPLC
Brand
Brand > Agilent
Chromatography Component
Chromatography Component > Auto Samplers