Agilent 1100 HPLC G1314A Variable Wavelength Detector
Wavelength Range
190 - 600 nm
Wavelength Accuracy
± 1 nm
Drift
3 × 10-4AU/hr at 254 nm
- Designed for high sensitivity, low baseline drift, and a wide linear range.
- Allows for reliable simultaneous quantitation of main and side products as well as impurities.
- Ensures highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm.
- Early maintenance feedback monitors the usage of specific components and alerts when maintenance is needed.
- EMF counter for the lamp provides visual feedback in the user interface when the user-selectable limit is exceeded.
- Electronic records of maintenance and errors facilitates efficient tracking and troubleshooting.
The
Agilent 1100 HPLC G1314A Variable Wavelength Detector lowers detection limits
with simplified optics for high sensitivity, low baseline drift, and wide
linear range. This wide linear range allows for reliable simultaneous
quantitation of main and side products and impurities. The Agilent 1100 VWD’s minimum
baseline noise gives it the highest baseline stability for the lowest detection
limits. This VWD offers programmable wavelength switching for sensitivity and
optimized selectivity optimized to each analyte’s elution, along with stop-flow
wavelength scanning for quick wavelength optimization.
Key features include: deuterium lamp for highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm; optional flow-cell cartridges depending on application needs; easy front access to lamp and flow cell for fast replacement; and built-in holmium oxide filter for fast wavelength accuracy verification.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Agilent 1100 HPLC G1314A Variable Wavelength Detector includes:
- > Firmware Version 07.02 (Can be changed upon request)
- > Flow Cell
- > UV Lamp
- > Detector Calibration Report
- > Lab Advisor Diagnostic Report
- > Lan Cable / Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Agilent 1100 HPLC G1314A Variable Wavelength Detector Specifications
Detection type
|
Double-beam photometer
|
Light Source
|
Deuterium lamp
|
Wavelength Range
|
190 - 600 nm
|
Short term noise (ASTM) Single
and Multi-Wavelength
|
± 0.75 × 10-5AU at 254 nm
|
Drift
|
3 × 10-4AU/hr at 254 nm
|
Linear Absorbance range
|
> 2 AU (5%) upper limit
|
Wavelength accuracy
|
± 1 nm
|
Slit width
|
1, 2, 4 , 8, 16 nm
|
Band Width
|
6.5 nm typical
|
Diode Width
|
< 1 nm
|
Flow Cells
|
Standard: 14-µl volume, 10-mm
cell path length and 40 bar (588 psi) pressure maximum High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
|
Agilent 1100 HPLC VWD ManualClick Here to View all the Technical Specs for the G1314A VWD